roTEAMnet

Intern, Medium Voltage Test Engineering

heron-power · Scotts Valley

Normă întreagă

Formulări din sursă, separat de potrivirea profesională. Remote nu înseamnă automat eligibilitate globală sau program flexibil.

Sursa originală: Ashby · Publicat 2026-09-30 · Ultima verificare 2026-11-23 19:18 UTC

La sediuStagiuInternship, practică & studențiNormă întreagăheron-power

Compară cerințele cu experiența ta, pregătește documentul și păstrează oportunitatea la candidaturi. Tu trimiți candidatura.

What to Expect

Heron Power is a startup company building cutting-edge power electronics for the 21st-century grid. We aim to de-bottleneck the growth of electricity generation and consumption with scalable, innovative, and less costly hardware solutions, accelerating the electrification of everything.

Our first goal is to build better converters (inverters & rectifiers) to connect large-scale renewables, storage, and loads to the grid. Heron’s leadership team is made up of seasoned veterans who have designed and shipped gigawatts of power conversion products over the past decade.

We understand that no one individual knows everything. We will all learn a lot together and from each other. We strive to build a collaborative, enriching environment conducive to personal, technical, and career growth. You can expect to work in a dynamic environment, driven by first principles engineering, solving difficult problems—with a strong bias toward hands-on execution and learning by doing.

Job Overview

You will build and operate the high-voltage test infrastructure we use to characterize and qualify insulation systems in medium-voltage power electronics. This role owns a real piece of the reliability validation loop: test bench setup, dielectric characterization campaigns, degradation analysis, and structured failure mode documentation. You will work with equipment and methodologies that most EE programs never expose students to—and you will be building the data foundation that informs how we design insulation systems for grid-tied hardware at scale.

How You Will Contribute

Medium Voltage Test Infrastructure

Design, build, and operate medium-voltage test benches: HV power supplies, measurement dividers, partial discharge detection systems, protective earthing schemes, and safety interlocks.

Own bench system design: HV clearances, grounding architecture, protection strategy, measurement integrity, and safe operating procedures.

Build and document test fixtures for cable assemblies, busbars, insulation specimens, and HV subcomponents—to a standard someone else can operate safely.

Learn and strictly enforce MV lab safety protocols: electrical clearances, interlock design, lockout/tagout, and safe approach procedures.

Dielectric Characterization & Testing

Execute dielectric strength tests—AC/DC withstand and impulse—against defined acceptance criteria; own data collection and reporting.

Perform insulation resistance, polarization index, and dielectric loss (tan δ) measurements using HV megohmmeters, LCR bridges, and dielectric analyzers.

Run partial discharge (PD) measurements end to end: system setup, acquisition, PRPD pattern generation, and first-pass interpretation.

Execute accelerated aging and environmental stress campaigns on insulating materials under thermal, humidity, and combined stress conditions.

Degradation Analysis & Closing the Loop

Track and analyze degradation trends across test campaigns: capacitance drift, tan δ evolution, PD magnitude and repetition rate, breakdown statistics.

Build structured data workflows and visualizations that clearly show baseline, stressed, and failed states—and make the trajectory actionable.

Produce failure mode documentation: what failed, what the failure mechanism was, what the precursor signals were, and what changed.

Partner with design and materials engineering to translate test findings into corrective actions and design improvements.

Materials Characterization & Inspection

Support post-failure analysis: specimen dissection, cross-section preparation, visual and microscopic inspection, comparison against reference specimens.

Maintain sample tracking logs, calibration records, and test procedure documentation to production-quality standards.

What You Will Bring

We prioritize a strong foundation in first principles, practical skill, an inquisitive mindset, and a proactive attitude. We care as much—or more—about how you work as what you already know.

Must-Have

Pursuing a BS or MS in Electrical Engineering, Physics, or Materials Science.

Coursework in electromagnetics, dielectrics, or high-voltage engineering—or demonstrated independent study in this area.

Genuine technical interest in high-voltage physics, insulation behavior, and failure mechanisms.

Strong debugging instincts: ability to isolate failure modes, design targeted experiments, and close findings into documented root causes.

Detail-oriented and safety-conscious—MV lab work demands rigor and discipline.

Nice-to-Haves

Exposure to partial discharge theory, dielectric spectroscopy, or high-voltage lab techniques.

Familiarity with IEC or IEEE dielectric testing standards (IEC 60243, IEC 60270, or similar).

Experience with data analysis and visualization in Python or MATLAB.

Prior lab research in materials characterization, high-voltage systems, or power electronics.

If you are passionate about technology and enjoy working in a fast-paced environment, we would love to hear from you. Join us in accelerating the electrification of everything at Heron Power.
Aplică pe site-ul original

Ashby

Aplică cu un cont gratuit

Un cont gratuit îți verifică potrivirea cu jobul, îl salvează în lista de candidaturi și lasă pilotul automat să găsească joburi asemănătoare. Membrii eligibili văd linkul original de aplicare.

Creează cont Autentificare

Cookie-urile esențiale susțin sesiunea și securitatea. Google Analytics și măsurarea publicitară Meta pornesc doar conform alegerilor tale separate. Nu trimitem texte din CV sau date de contact.

Cookies esențiale · mereu active

Sesiunea, protecția CSRF și preferința pentru cookies susțin accesul în cont și alegerea făcută aici.

Google Analytics măsoară pagini publice și acțiuni predefinite după acord. Excludem căutările, CV-urile, ID-urile de cont și tokenurile de plată. Stocarea publicitară și personalizarea rămân dezactivate.

Cu acordul pentru marketing, Meta primește evenimente PageView pe anumite pagini publice de prezentare, URL-ul și informații de rețea/browser pentru măsurarea reclamelor. PageView exclude paginile de CV, căutare joburi, cont și plăți. Potrivirea automată și colectarea automată de evenimente sunt dezactivate. Datele pot fi procesate în afara țării. Refuzul nu limitează instrumentele.

Cu acordul pentru marketing, Google Ads măsoară conturile verificate și achizițiile confirmate printr-un identificator anonim și suma/moneda plății. Fără CV sau date de contact.

Cu acordul pentru marketing, Meta poate păstra identificatorii clicurilor publicitare pe pagina de înscriere pentru atribuirea unui cont verificat ulterior. Deschiderea formularului nu este numărată ca înregistrare.

Cu acordul pentru marketing, Meta măsoară și conturile verificate pe pagina principală a spațiului de lucru, printr-un identificator anonim. Nu primește CV sau date de contact.

Alegerea este păstrată 180 de zile. O poți modifica sau retrage oricând din Setări cookies. Refuzul analizei nu limitează instrumentele de carieră.

Politica de cookies