roTEAMnet

Staff Power Systems Site Integration Engineer

Mainspring Energy · United States

Normă întreagă

Formulări din sursă, separat de potrivirea profesională. Remote nu înseamnă automat eligibilitate globală sau program flexibil.

Sursa originală: Himalayas · Publicat 2026-10-19 · Ultima verificare 2026-11-17 03:20 UTC

RemoteLead / expertUSD 135,265 – 159,135 / an5+ aniInginer electric & sisteme energeticeNormă întreagăMainspring Energy Statele Unite ale Americii

Compară cerințele cu experiența ta, pregătește documentul și păstrează oportunitatea la candidaturi. Tu trimiți candidatura.

About Mainspring

Mainspring Energy manufactures and delivers fuel-flexible, low-emissions local power solutions that rapidly add new capacity and deliver reliable, affordable, and sustainable electric power. The company began commercial shipments of its Mainspring Linear Generators in 2020 and today has hundreds of megawatts in advanced development and field operations for leading Fortune 500 companies, data centers, and utilities. Mainspring also partners with global energy leaders including AEP, NextEra Energy Resources, Schneider Electric, and more.

The core values that ground our work, guide our decisions, and connect us together:

Pragmatic Optimism

Excellence without Ego

Proactive Collaboration

Job Overview

Site Integration Engineers report to the Project Engineering Manager within the Project Delivery department. A key enabler of Mainspring’s mission is the ability of its team to deliver solutions based on our linear generator technology that solve customer problems in the cross-section of resiliency and clean power supply.

The project engineering team provides the technical expertise, guidance, and support to deploy linear generators into the field efficiently—building customer confidence and enabling future scalability. This role owns site-level readiness after construction is complete, ensuring that all mechanical, electrical, control, and communication systems are fully integrated, validated, and ready to transition into commissioning and operation. Generator commissioning is performed by a separate team; this role ensures the site is ready for it. Acting as the technical integration authority on site, this role bridges engineering design intent and real-world system operation.

Responsibilities

This role will be responsible for:

Interpreting technical project details, including scopes of work, sequences of operation, control narratives, and engineering drawings (site plans, P&IDs, single-line, and three-line diagrams), and serving as the controls subject matter expert in design reviews

Verifying relay settings, meter configurations, and controller programming delivered by third-party integrators against approved settings files and design documents

Owning site readiness on assigned projects by validating installation quality and accuracy of balance-of-plant systems such as fuel, electrical, metering, protection relays, and communications; developing punch lists and driving issues to closure when discrepancies are found

Validating electrical and mechanical installations against drawings and specifications by witnessing and/or reviewing results of checks such as wiring and termination verification, grounding, insulation resistance and continuity testing, phase rotation, and electrical acceptance test (NETA) reports; and equipment setting and anchoring, gas piping pressure and leak tests, purging, ventilation and exhaust, and fuel regulator setup

Configuring equipment and verifying functional readiness of site-level control and communication systems prior to energization, including troubleshooting industrial communication networks (e.g., Modbus TCP/IP, EtherNet/IP, Profibus, OPC-UA)

Supporting integration with customer PLC/SCADA/HMI platforms (e.g., Ignition, SEL RTAC, Siemens WinCC, AVEVA Wonderware, Rockwell FactoryTalk, Schneider EcoStruxure) for system monitoring and control

Coordinating handoff to the generator commissioning team, confirming all site-level prerequisites are complete before units are started, and keeping project stakeholders updated on readiness status and next steps

Planning Site Acceptance Testing (SAT) and system-level validation, defining acceptance criteria for customer and utility witness testing, and confirming that as-built operation matches design intent

Supporting Permission to Operate (PTO) by compiling documentation based on utility requirements and building an accurate submission package for the Interconnection team to issue to the utility

Owning site QA/QC documentation and ensuring systems are fully validated and ready for turnover to operations and the customer

Establishing repeatable processes, including ready-for-commissioning and ready-for-testing checklists, lookahead dashboards, SAT templates, equipment configuration and how-to guides, site procedures, etc

Travelling to project sites as needed to confirm readiness and perform necessary testing

Job Qualifications and Experience

B.S. degree in Electrical, Controls, Mechatronics, or a related engineering discipline. Equivalent field experience may be substituted

5+ years in pre-commissioning, site commissioning, field applications, or controls engineering on power generation, battery storage, solar, microgrid, or industrial facility projects

Experience configuring, integrating, and troubleshooting devices and platforms such as:

Protective relays and automation controllers: SEL (relays, RTAC), GE Multilin, Beckwith, or ABB.

Revenue and power quality meters: SEL-735, Schneider ION, GE kV2c, or Itron

PLCs: Allen-Bradley ControlLogix/CompactLogix, Siemens S7, or Schneider Modicon

SCADA/HMI: Ignition, Siemens WinCC, AVEVA (Wonderware), or Rockwell FactoryTalk View

Working knowledge of industrial communication protocols (Modbus TCP/IP, EtherNet/IP, Profibus, OPC-UA, DNP3) and OT networking

Ability to interpret single-line and three-line diagrams, P&IDs, control narratives, and sequences of operation

Understanding of balance-of-plant systems, including fuel/gas, low- and medium-voltage electrical, metering, protection, and communications, with the ability to read construction plan sets and acceptance test reports and a working knowledge of NEC and NFPA 37/54

Experience planning and documenting Site Acceptance Testing and supporting utility witness testing for PTO

Familiarity with field safety practices and energization standards and procedures (e.g., NFPA 70E, lockout/tagout), including Lockout/Tagout (LOTO) procedures and arc flash hazard awareness

Strong analytical problem-solving skills with the ability to safely use standard electrical test equipment (multimeters, phase rotation meter, network cable/fiber tester, power quality analyzers) in an active construction or live-plant environment

Strong documentation and communication skills, and comfortable coordinating contractors, integrators, and customers on site

Self-directed, with an ownership mindset and enthusiasm for building repeatable processes within a growing team

Does your experience not meet all of our posted requirements? Studies have shown that some people are less likely to apply to positions unless they meet every listed requirement. At Mainspring, we are committed to building a diverse, inclusive, flexible, and collaborative environment, so if you want to help us transition the world to clean and affordable electricity, and don’t meet all posted requirements for a particular role, we’d still love to hear from you. Mainspring can sometimes be flexible enough to shift responsibilities for the right person, or otherwise identify open or upcoming roles that may better fit your professional background.

In more traditional words, Mainspring Energy, Inc is an Equal Opportunity Employer. All qualified applicants will receive consideration for employment without regard to race, color, religion, sex, sexual orientation, gender identity, national origin, or protected veteran status and will not be discriminated against on the basis of disability.

This compensation and benefits information is based on Mainspring Energy's estimate as of the date of publication and may be modified in the future. We generally do not negotiate on salary once we have made an offer. The level of pay within the range will depend on a variety of job-related factors that may include location, relevant prior experience and/or education, or particular skills and expertise. New hires joining the company tend to be paid within the starting base pay range noted above, with opportunities to increase pay over time based on development of additional skills, competencies, and company-specific knowledge.

Originally posted on Himalayas
Aplică pe site-ul original

Himalayas

Aplică cu un cont gratuit

Un cont gratuit îți verifică potrivirea cu jobul, îl salvează în lista de candidaturi și lasă pilotul automat să găsească joburi asemănătoare. Membrii eligibili văd linkul original de aplicare.

Creează cont Autentificare

Cookie-urile esențiale susțin sesiunea și securitatea. Google Analytics și măsurarea publicitară Meta pornesc doar conform alegerilor tale separate. Nu trimitem texte din CV sau date de contact.

Cookies esențiale · mereu active

Sesiunea, protecția CSRF și preferința pentru cookies susțin accesul în cont și alegerea făcută aici.

Google Analytics măsoară pagini publice și acțiuni predefinite după acord. Excludem căutările, CV-urile, ID-urile de cont și tokenurile de plată. Stocarea publicitară și personalizarea rămân dezactivate.

Cu acordul pentru marketing, Meta primește evenimente PageView pe anumite pagini publice de prezentare, URL-ul și informații de rețea/browser pentru măsurarea reclamelor. PageView exclude paginile de CV, căutare joburi, cont și plăți. Potrivirea automată și colectarea automată de evenimente sunt dezactivate. Datele pot fi procesate în afara țării. Refuzul nu limitează instrumentele.

Cu acordul pentru marketing, Google Ads măsoară conturile verificate și achizițiile confirmate printr-un identificator anonim și suma/moneda plății. Fără CV sau date de contact.

Cu acordul pentru marketing, Meta poate păstra identificatorii clicurilor publicitare pe pagina de înscriere pentru atribuirea unui cont verificat ulterior. Deschiderea formularului nu este numărată ca înregistrare.

Cu acordul pentru marketing, Meta măsoară și conturile verificate pe pagina principală a spațiului de lucru, printr-un identificator anonim. Nu primește CV sau date de contact.

Alegerea este păstrată 180 de zile. O poți modifica sau retrage oricând din Setări cookies. Refuzul analizei nu limitează instrumentele de carieră.

Politica de cookies