roTEAMnet

Electrical Commissioning Lead

LotusWorks · Grafton, Wisconsin

Opdracht / B2B

Alleen de formulering van de bron; dit staat los van professionele geschiktheid. Op afstand werken betekent niet automatisch wereldwijde geschiktheid of flexibele uren.

Originele bron: Greenhouse · Gepubliceerd 2026-10-01 · Laatst gecontroleerd 2026-11-24 02:08 UTC

Werkvorm niet gespecificeerdLead / staff10+ jrTechniek & R&D-ingenieursLotusWorks Verenigde Staten

Vergelijk de vereisten met uw ervaring, bereid uw document voor en bewaar de vacature in uw sollicitaties. U dient de sollicitatie zelf in.

LotusWorks is an Engineering Services provider specializing in managing Commissioning, Construction Services, Calibration, Operations & Maintenance scopes of work within global manufacturing facilities. LotusWorks operates globally across EMEA and North America partnering with the world's leading manufacturers across the Semiconductor, Pharmaceutical & Biologics, Medical Device and Data Center sectors. Our team of Engineering and Technical professionals is immersed in cutting-edge technologies and innovations. LotusWorks is committed to a diverse and inclusive workplace, integral to our people-first approach.

LotusWorks is seeking an experienced Electrical Commissioning Lead to support the commissioning of critical electrical systems within a large-scale data center environment. This role will lead electrical commissioning activities from design review and equipment startup through functional performance testing, Integrated Systems Testing (IST), and final turnover. The position will focus on MV/LV switchgear, transformers, generators, UPS systems, ATS/STS, PDUs, busway, EPMS/SCADA, and related electrical distribution systems. The successful candidate will lead Cx engineers and technicians while coordinating with electrical contractors, NETA testing firms, controls integrators, OEM representatives, and the broader commissioning team to ensure systems are tested, issues are resolved, and the facility is ready for operations.

Responsibilities:

Planning & pre-construction

Review electrical design documents (one-lines, schedules, specs, protection/coordination study, arc flash study) for commission ability, testing access, and constructability.

Develop the electrical section of the Cx Plan, including test sequencing, prerequisites, and Level 1–5 scope definitions.

Write or review electrical Cx specifications and Division 26 Cx requirements.

Define and track factory witness testing (FWT) requirements for switchgear, gens, UPS, PDUs, STS, ATS, busway.

Coordinate with NETA-certified testing contractor scope; establish the boundary between NETA acceptance testing and Cx functional testing.

Build the electrical Cx schedule and integrate it into the master schedule; identify long-lead test equipment (load banks, primary injection sets) and utility coordination milestones.

Test script development

Author or approve Level 3 (start-up), Level 4 (functional performance), and Level 5 (IST) scripts for: MV/LV switchgear, transformers, generators and paralleling gear, ATS/STS, UPS and batteries, PDUs/RPPs, busway, lighting controls, grounding/bonding, EPMS/SCADA, fire alarm interface, and metering.

Define pass/fail criteria tied to the Basis of Design and OPR (transfer times, voltage/frequency tolerances, battery runtime, protection settings).

Develop failure-mode and concurrent-maintainability test sequences (loss of utility, breaker failure, single-cord vs. dual-cord, load transfer cascades).

Field execution

Witness and document Level 2/3 installation verification, energization, and start-up.

Direct Level 4 functional testing; verify protection settings match the coordination study; witness relay testing and primary/secondary injection.

Lead electrical portions of Level 5 IST, including load bank testing, pull-the-plug tests, and utility-loss scenarios in coordination with the mechanical lead.

Manage energization and LOTO coordination with the GC/EC safety program; enforce switching orders and approved MOPs.

Verify EPMS/BMS point-to-point, alarm mapping, and trending before functional tests begin.

Issues & documentation

Own the electrical issues log: log, classify (safety/critical/major/minor), track to closure, and verify corrective action via retest.

Review and approve electrical Cx test reports, NETA reports, and vendor start-up reports for completeness and accuracy.

Contribute the electrical sections of the Final Cx Report, including deferred/seasonal tests and outstanding items.

Verify O&M manuals, as-builts, settings files (relay, UPS, gen controllers), and training are delivered before turnover.

Coordination & leadership

Daily interface with the electrical contractor, factory service reps (gen, UPS, switchgear OEMs), NETA firm, controls integrator, and the mechanical Cx lead.

Chair electrical Cx coordination meetings; report progress, readiness, and risk to the Cx Manager and owner.

Supervise and QC the work of electrical Cx engineers/technicians assigned to the project.

Escalate schedule, safety, or design conflicts early with recommended paths forward.

Skills Required:

8–10+ years of experience in electrical construction, testing, or commissioning, with mission-critical/data center experience.

Strong understanding of L1–L5 commissioning, including startup, functional performance testing, IST, and turnover.

Working knowledge of NETA ATS, NFPA 70/70B/70E/110, IEEE 1584, and relevant utility standards.

Ability to read and interpret one-line diagrams, control schematics, relay settings, and protection/coordination studies.

Experience with MV/LV switchgear, transformers, generators, and paralleling gear.

Experience with UPS, batteries, ATS/STS, PDUs/RPPs, busway, and electrical distribution systems.

Familiarity with EPMS/SCADA, BMS interfaces, metering, alarm mapping, and electrical testing.

ACG CxA, BCxA CCP, NETA Level III/IV, or AEE CxP certification preferred.

Education / Licenses / Certifications

Relevant experience in electrical construction, testing, or commissioning will be considered in lieu of a specific degree.

ACG CxA, BCxA CCP, NETA Level III/IV, or AEE CxP certification preferred.

OSHA 30 required.

Proof of education, licenses, and certifications will be required where applicable.

Benefits:

Medical, Dental and Vision Insurance

Life, Short-Term, Long-Term Disability Insurance

Training and Education Assistance

401k Retirement Plan

Extra Annual Leave with Years of Service

Maternity/Paternity Leave

Recognition Rewards

#INDHP

LotusWorks is an equal opportunity employer and prohibits discrimination and harassment of any kind. We are committed to creating a diverse and inclusive workplace where all employees feel valued, respected, and empowered.
Solliciteer op de oorspronkelijke website

Greenhouse

Solliciteer met een gratis account

Een gratis account toont de originele sollicitatielink aan in aanmerking komende leden, controleert je geschiktheid voor deze functie, slaat deze op in je tracker en laat Autopilot meer soortgelijke vacatures vinden.

Account aanmaken Inloggen

Essentiële cookies ondersteunen uw sessie en beveiliging. Google Analytics en advertentiemetingen van Meta worden alleen geladen met uw afzonderlijke toestemming. Tekst uit uw cv en contactgegevens worden niet verzonden.

Essentiële cookies · altijd actief

Sessie, CSRF-beveiliging en uw cookievoorkeur. Deze ondersteunen de accounttoegang en de keuze die u hier maakt.

Google Analytics meet openbare pagina's en vooraf gedefinieerde acties na toestemming. Zoektekst, cv-inhoud, account-ID's en betalingstokens zijn uitgesloten. Advertentieopslag en personalisatie blijven uitgeschakeld.

Met toestemming voor marketing ontvangt Meta PageView-gebeurtenissen op geselecteerde openbare presentatiepagina's, de pagina-URL en netwerk-/browsergegevens om advertenties te meten. PageView sluit pagina's voor cv's, vacatures, accounts en betalingen uit. Automatische geavanceerde matching en automatische gebeurtenisverzameling zijn uitgeschakeld. Meta kan deze informatie buiten uw land verwerken. Weigeren beperkt het gebruik van de functies niet.

Met marketingtoestemming meet Google Ads geverifieerde accounts en bevestigde aankopen met een anonieme gebeurtenis-ID en bedrag/valuta. Geen cv- of contactgegevens.

Met marketingtoestemming kan Meta advertentieklik-ID’s op de registratiepagina opslaan om een latere geverifieerde aanmelding toe te wijzen. Het openen van het formulier telt niet als registratie.

Met marketingtoestemming meet Meta ook geverifieerde accounts op de werkruimte-startpagina met een anonieme gebeurtenis-ID. Geen cv- of contactgegevens.

Uw keuze wordt 180 dagen bewaard. Wijzig of trek deze op elk gewenst moment in via Cookie-instellingen. Het weigeren van analytics beperkt de loopbaantools niet.

Cookiebeleid