roTEAMnet

Electrical Commissioning Lead

LotusWorks · Grafton, Wisconsin

Contratto / B2B

Solo formulazione originale; questo è indipendente dall'idoneità professionale. Il lavoro da remoto non implica automaticamente l'idoneità a livello globale o orari flessibili.

Fonte originale: Greenhouse · Pubblicato 2026-10-01 · Ultimo controllo 2026-11-24 02:08 UTC

Modalità di lavoro non specificataLead / staff10+ anniIngegneria generale e R&DLotusWorks Stati Uniti

Verifica i requisiti rispetto alla tua esperienza, prepara il documento e conserva l'opportunità nelle tue candidature. Invierai tu stesso la candidatura.

LotusWorks is an Engineering Services provider specializing in managing Commissioning, Construction Services, Calibration, Operations & Maintenance scopes of work within global manufacturing facilities. LotusWorks operates globally across EMEA and North America partnering with the world's leading manufacturers across the Semiconductor, Pharmaceutical & Biologics, Medical Device and Data Center sectors. Our team of Engineering and Technical professionals is immersed in cutting-edge technologies and innovations. LotusWorks is committed to a diverse and inclusive workplace, integral to our people-first approach.

LotusWorks is seeking an experienced Electrical Commissioning Lead to support the commissioning of critical electrical systems within a large-scale data center environment. This role will lead electrical commissioning activities from design review and equipment startup through functional performance testing, Integrated Systems Testing (IST), and final turnover. The position will focus on MV/LV switchgear, transformers, generators, UPS systems, ATS/STS, PDUs, busway, EPMS/SCADA, and related electrical distribution systems. The successful candidate will lead Cx engineers and technicians while coordinating with electrical contractors, NETA testing firms, controls integrators, OEM representatives, and the broader commissioning team to ensure systems are tested, issues are resolved, and the facility is ready for operations.

Responsibilities:

Planning & pre-construction

Review electrical design documents (one-lines, schedules, specs, protection/coordination study, arc flash study) for commission ability, testing access, and constructability.

Develop the electrical section of the Cx Plan, including test sequencing, prerequisites, and Level 1–5 scope definitions.

Write or review electrical Cx specifications and Division 26 Cx requirements.

Define and track factory witness testing (FWT) requirements for switchgear, gens, UPS, PDUs, STS, ATS, busway.

Coordinate with NETA-certified testing contractor scope; establish the boundary between NETA acceptance testing and Cx functional testing.

Build the electrical Cx schedule and integrate it into the master schedule; identify long-lead test equipment (load banks, primary injection sets) and utility coordination milestones.

Test script development

Author or approve Level 3 (start-up), Level 4 (functional performance), and Level 5 (IST) scripts for: MV/LV switchgear, transformers, generators and paralleling gear, ATS/STS, UPS and batteries, PDUs/RPPs, busway, lighting controls, grounding/bonding, EPMS/SCADA, fire alarm interface, and metering.

Define pass/fail criteria tied to the Basis of Design and OPR (transfer times, voltage/frequency tolerances, battery runtime, protection settings).

Develop failure-mode and concurrent-maintainability test sequences (loss of utility, breaker failure, single-cord vs. dual-cord, load transfer cascades).

Field execution

Witness and document Level 2/3 installation verification, energization, and start-up.

Direct Level 4 functional testing; verify protection settings match the coordination study; witness relay testing and primary/secondary injection.

Lead electrical portions of Level 5 IST, including load bank testing, pull-the-plug tests, and utility-loss scenarios in coordination with the mechanical lead.

Manage energization and LOTO coordination with the GC/EC safety program; enforce switching orders and approved MOPs.

Verify EPMS/BMS point-to-point, alarm mapping, and trending before functional tests begin.

Issues & documentation

Own the electrical issues log: log, classify (safety/critical/major/minor), track to closure, and verify corrective action via retest.

Review and approve electrical Cx test reports, NETA reports, and vendor start-up reports for completeness and accuracy.

Contribute the electrical sections of the Final Cx Report, including deferred/seasonal tests and outstanding items.

Verify O&M manuals, as-builts, settings files (relay, UPS, gen controllers), and training are delivered before turnover.

Coordination & leadership

Daily interface with the electrical contractor, factory service reps (gen, UPS, switchgear OEMs), NETA firm, controls integrator, and the mechanical Cx lead.

Chair electrical Cx coordination meetings; report progress, readiness, and risk to the Cx Manager and owner.

Supervise and QC the work of electrical Cx engineers/technicians assigned to the project.

Escalate schedule, safety, or design conflicts early with recommended paths forward.

Skills Required:

8–10+ years of experience in electrical construction, testing, or commissioning, with mission-critical/data center experience.

Strong understanding of L1–L5 commissioning, including startup, functional performance testing, IST, and turnover.

Working knowledge of NETA ATS, NFPA 70/70B/70E/110, IEEE 1584, and relevant utility standards.

Ability to read and interpret one-line diagrams, control schematics, relay settings, and protection/coordination studies.

Experience with MV/LV switchgear, transformers, generators, and paralleling gear.

Experience with UPS, batteries, ATS/STS, PDUs/RPPs, busway, and electrical distribution systems.

Familiarity with EPMS/SCADA, BMS interfaces, metering, alarm mapping, and electrical testing.

ACG CxA, BCxA CCP, NETA Level III/IV, or AEE CxP certification preferred.

Education / Licenses / Certifications

Relevant experience in electrical construction, testing, or commissioning will be considered in lieu of a specific degree.

ACG CxA, BCxA CCP, NETA Level III/IV, or AEE CxP certification preferred.

OSHA 30 required.

Proof of education, licenses, and certifications will be required where applicable.

Benefits:

Medical, Dental and Vision Insurance

Life, Short-Term, Long-Term Disability Insurance

Training and Education Assistance

401k Retirement Plan

Extra Annual Leave with Years of Service

Maternity/Paternity Leave

Recognition Rewards

#INDHP

LotusWorks is an equal opportunity employer and prohibits discrimination and harassment of any kind. We are committed to creating a diverse and inclusive workplace where all employees feel valued, respected, and empowered.
Candidati sul sito web originale

Greenhouse

Candidati con un account gratuito

Un account gratuito mostra il link di candidatura originale agli utenti idonei, valuta la tua affinità con l'offerta, la salva nel tuo tracker e consente ad Autopilot di trovare altre offerte simili.

Crea account Accedi

I cookie essenziali supportano la sessione e la sicurezza. Google Analytics e la misurazione pubblicitaria di Meta vengono caricati solo previo consenso specifico. Il testo del CV e i dati di contatto non vengono inviati.

Cookie essenziali · sempre attivi

Sessione, protezione CSRF e preferenze sui cookie. Questi elementi supportano l'accesso all'account e la scelta effettuata in questa sede.

Google Analytics misura le pagine pubbliche e le azioni predefinite previo consenso. Il testo di ricerca, il contenuto del CV, gli ID account e i token di pagamento sono esclusi. L'archiviazione a fini pubblicitari e la personalizzazione restano disattivate.

Con il consenso alle attività di marketing, Meta riceve gli eventi PageView su pagine di presentazione pubbliche selezionate, l'URL della pagina e le informazioni di rete/browser, al fine di misurare l'efficacia pubblicitaria. PageView esclude le pagine di CV, ricerca di lavoro, account e pagamenti. Il matching automatico e la raccolta automatica degli eventi sono disattivati. Meta potrebbe elaborare queste informazioni al di fuori del tuo paese. Il rifiuto non limita l'uso degli strumenti.

Con consenso marketing, Google Ads misura account verificati e acquisti confermati tramite ID anonimo e importo/valuta. Nessun CV o dato di contatto.

Con consenso marketing, Meta può memorizzare gli identificatori dei clic pubblicitari nella pagina di registrazione per attribuire un account verificato successivo. Aprire il modulo non conta come registrazione.

Con consenso marketing, Meta misura anche gli account verificati nella pagina iniziale dello spazio di lavoro tramite un ID anonimo. Nessun CV o dato di contatto.

La tua scelta viene memorizzata per 180 giorni. Puoi modificarla o revocarla in qualsiasi momento tramite le Impostazioni cookie. Il rifiuto dei cookie di analisi non limita gli strumenti di carriera.

Informativa sui cookie