roTEAMnet

Intern, Medium Voltage Test Engineering

heron-power · Scotts Valley

Full-time

Solo formulazione originale; questo è indipendente dall'idoneità professionale. Il lavoro da remoto non implica automaticamente l'idoneità a livello globale o orari flessibili.

Fonte originale: Ashby · Pubblicato 2026-09-30 · Ultimo controllo 2026-11-23 19:18 UTC

Verifica i requisiti rispetto alla tua esperienza, prepara il documento e conserva l'opportunità nelle tue candidature. Invierai tu stesso la candidatura.

What to Expect

Heron Power is a startup company building cutting-edge power electronics for the 21st-century grid. We aim to de-bottleneck the growth of electricity generation and consumption with scalable, innovative, and less costly hardware solutions, accelerating the electrification of everything.

Our first goal is to build better converters (inverters & rectifiers) to connect large-scale renewables, storage, and loads to the grid. Heron’s leadership team is made up of seasoned veterans who have designed and shipped gigawatts of power conversion products over the past decade.

We understand that no one individual knows everything. We will all learn a lot together and from each other. We strive to build a collaborative, enriching environment conducive to personal, technical, and career growth. You can expect to work in a dynamic environment, driven by first principles engineering, solving difficult problems—with a strong bias toward hands-on execution and learning by doing.

Job Overview

You will build and operate the high-voltage test infrastructure we use to characterize and qualify insulation systems in medium-voltage power electronics. This role owns a real piece of the reliability validation loop: test bench setup, dielectric characterization campaigns, degradation analysis, and structured failure mode documentation. You will work with equipment and methodologies that most EE programs never expose students to—and you will be building the data foundation that informs how we design insulation systems for grid-tied hardware at scale.

How You Will Contribute

Medium Voltage Test Infrastructure

Design, build, and operate medium-voltage test benches: HV power supplies, measurement dividers, partial discharge detection systems, protective earthing schemes, and safety interlocks.

Own bench system design: HV clearances, grounding architecture, protection strategy, measurement integrity, and safe operating procedures.

Build and document test fixtures for cable assemblies, busbars, insulation specimens, and HV subcomponents—to a standard someone else can operate safely.

Learn and strictly enforce MV lab safety protocols: electrical clearances, interlock design, lockout/tagout, and safe approach procedures.

Dielectric Characterization & Testing

Execute dielectric strength tests—AC/DC withstand and impulse—against defined acceptance criteria; own data collection and reporting.

Perform insulation resistance, polarization index, and dielectric loss (tan δ) measurements using HV megohmmeters, LCR bridges, and dielectric analyzers.

Run partial discharge (PD) measurements end to end: system setup, acquisition, PRPD pattern generation, and first-pass interpretation.

Execute accelerated aging and environmental stress campaigns on insulating materials under thermal, humidity, and combined stress conditions.

Degradation Analysis & Closing the Loop

Track and analyze degradation trends across test campaigns: capacitance drift, tan δ evolution, PD magnitude and repetition rate, breakdown statistics.

Build structured data workflows and visualizations that clearly show baseline, stressed, and failed states—and make the trajectory actionable.

Produce failure mode documentation: what failed, what the failure mechanism was, what the precursor signals were, and what changed.

Partner with design and materials engineering to translate test findings into corrective actions and design improvements.

Materials Characterization & Inspection

Support post-failure analysis: specimen dissection, cross-section preparation, visual and microscopic inspection, comparison against reference specimens.

Maintain sample tracking logs, calibration records, and test procedure documentation to production-quality standards.

What You Will Bring

We prioritize a strong foundation in first principles, practical skill, an inquisitive mindset, and a proactive attitude. We care as much—or more—about how you work as what you already know.

Must-Have

Pursuing a BS or MS in Electrical Engineering, Physics, or Materials Science.

Coursework in electromagnetics, dielectrics, or high-voltage engineering—or demonstrated independent study in this area.

Genuine technical interest in high-voltage physics, insulation behavior, and failure mechanisms.

Strong debugging instincts: ability to isolate failure modes, design targeted experiments, and close findings into documented root causes.

Detail-oriented and safety-conscious—MV lab work demands rigor and discipline.

Nice-to-Haves

Exposure to partial discharge theory, dielectric spectroscopy, or high-voltage lab techniques.

Familiarity with IEC or IEEE dielectric testing standards (IEC 60243, IEC 60270, or similar).

Experience with data analysis and visualization in Python or MATLAB.

Prior lab research in materials characterization, high-voltage systems, or power electronics.

If you are passionate about technology and enjoy working in a fast-paced environment, we would love to hear from you. Join us in accelerating the electrification of everything at Heron Power.
Candidati sul sito web originale

Ashby

Candidati con un account gratuito

Un account gratuito mostra il link di candidatura originale agli utenti idonei, valuta la tua affinità con l'offerta, la salva nel tuo tracker e consente ad Autopilot di trovare altre offerte simili.

Crea account Accedi

I cookie essenziali supportano la sessione e la sicurezza. Google Analytics e la misurazione pubblicitaria di Meta vengono caricati solo previo consenso specifico. Il testo del CV e i dati di contatto non vengono inviati.

Cookie essenziali · sempre attivi

Sessione, protezione CSRF e preferenze sui cookie. Questi elementi supportano l'accesso all'account e la scelta effettuata in questa sede.

Google Analytics misura le pagine pubbliche e le azioni predefinite previo consenso. Il testo di ricerca, il contenuto del CV, gli ID account e i token di pagamento sono esclusi. L'archiviazione a fini pubblicitari e la personalizzazione restano disattivate.

Con il consenso alle attività di marketing, Meta riceve gli eventi PageView su pagine di presentazione pubbliche selezionate, l'URL della pagina e le informazioni di rete/browser, al fine di misurare l'efficacia pubblicitaria. PageView esclude le pagine di CV, ricerca di lavoro, account e pagamenti. Il matching automatico e la raccolta automatica degli eventi sono disattivati. Meta potrebbe elaborare queste informazioni al di fuori del tuo paese. Il rifiuto non limita l'uso degli strumenti.

Con consenso marketing, Google Ads misura account verificati e acquisti confermati tramite ID anonimo e importo/valuta. Nessun CV o dato di contatto.

Con consenso marketing, Meta può memorizzare gli identificatori dei clic pubblicitari nella pagina di registrazione per attribuire un account verificato successivo. Aprire il modulo non conta come registrazione.

Con consenso marketing, Meta misura anche gli account verificati nella pagina iniziale dello spazio di lavoro tramite un ID anonimo. Nessun CV o dato di contatto.

La tua scelta viene memorizzata per 180 giorni. Puoi modificarla o revocarla in qualsiasi momento tramite le Impostazioni cookie. Il rifiuto dei cookie di analisi non limita gli strumenti di carriera.

Informativa sui cookie