roTEAMnet

Commissioning Engineer (Cathodic Protection)

Archirodon Group N.V · Abu Dhabi, United Arab Emirates

Full-timeContratto / B2B

Solo formulazione originale; questo è indipendente dall'idoneità professionale. Il lavoro da remoto non implica automaticamente l'idoneità a livello globale o orari flessibili.

Fonte originale: SmartRecruiters · Pubblicato 2026-11-18 · Ultimo controllo 2026-11-22 03:35 UTC

Modalità di lavoro non specificataLivello non specificato5+ anniIngegneria generale e R&DTempo pienoArchirodon Group N.V Emirati Arabi Uniti

Verifica i requisiti rispetto alla tua esperienza, prepara il documento e conserva l'opportunità nelle tue candidature. Invierai tu stesso la candidatura.

Company Description

Archirodon, having earned its reputation as a reliable and respected international contractor for more than a half century in the Engineering, Procurement and Construction (EPC) market, continues to create value to its stakeholders by executing complex EPC projects worldwide, in recognition of its superior standards of performance.

We have an outstanding record in completing major Energy (Oil & Gas – Power and Water), Marine, Infrastructure and Defense & Security projects around the globe and we pride ourselves on delivering over the years the kind of reliability and trust that the client has the right to expect from a major EPC contractor.

Job Description

Key Responsibilities

Prepare and review commissioning procedures, test plans, checklists, and inspection and test records for impressed current and galvanic anode CP systems.

Verify installation and readiness of transformer rectifiers, anode beds, junction boxes, test stations, reference electrodes, and associated cables against approved drawings.

Perform and witness pre-commissioning checks, including cable continuity and insulation resistance, polarity verification, anode bed resistance, and baseline structure-to-electrolyte potential measurements.

Energize and adjust transformer rectifiers, measure current output and protection potentials, and verify performance against project acceptance criteria.

Carry out ON and instant-OFF potential measurements, close-interval potential surveys (CIPS), and interference testing where required by the project.

Troubleshoot issues such as low protection levels, stray current interference, cable faults, and rectifier failures. Coordinate corrective work and retesting.

Coordinate commissioning activities and client witness inspections with construction, QA/QC, HSE, vendors, and operations teams.

Close commissioning punch items and prepare test reports, baseline readings, and handover dossiers.

Ensure all field activities comply with site HSE requirements, permit-to-work procedures, and electrical isolation requirements.

Knowledge & Skills:

Bachelor’s degree in Electrical, Materials, Corrosion, or a related engineering discipline.

Minimum 5 years of relevant experience in cathodic protection, including hands-on commissioning of CP systems on oil and gas projects.

Practical experience with both impressed current and galvanic anode systems, including field measurements, troubleshooting, and client handover.

Ability to interpret CP layouts, wiring diagrams, design calculations, and project specifications.

Familiarity with applicable AMPP and ISO standards and client specifications.

AMPP CP2 (Cathodic Protection Technician) certification or higher is preferred.

ADNOC project experience is an advantage.

IT / Software Skills:

Proficient in MS Office, Electrical Testing Tools (OMICRON/Doble software), and CMS/Commissioning tracking systems.

Basic knowledge of AutoCAD for red-line updates is beneficial.

Languages:

English – Full Professional Proficiency.

Qualifications

Qualifications & Experience:

Bachelor’s degree in electrical engineering from a recognized university.

ADNOC-approved or equivalent certification in commissioning or HV/LV safety will be an advantage.

Recognized training in Electrical Safety, Lockout–Tagout (LOTO), and PTW systems preferred.

Essential: Minimum 10–12 years’ experience in electrical commissioning within Oil & Gas, Power Generation, or Petrochemical projects.

Experience with EPC or PMC contractors under ADNOC, QP, or Aramco projects preferred.

Proven background in field execution, system energization, and documentation control.

Additional Information
Candidati sul sito web originale

SmartRecruiters

Candidati con un account gratuito

Un account gratuito mostra il link di candidatura originale agli utenti idonei, valuta la tua affinità con l'offerta, la salva nel tuo tracker e consente ad Autopilot di trovare altre offerte simili.

Crea account Accedi

I cookie essenziali supportano la sessione e la sicurezza. Google Analytics e la misurazione pubblicitaria di Meta vengono caricati solo previo consenso specifico. Il testo del CV e i dati di contatto non vengono inviati.

Cookie essenziali · sempre attivi

Sessione, protezione CSRF e preferenze sui cookie. Questi elementi supportano l'accesso all'account e la scelta effettuata in questa sede.

Google Analytics misura le pagine pubbliche e le azioni predefinite previo consenso. Il testo di ricerca, il contenuto del CV, gli ID account e i token di pagamento sono esclusi. L'archiviazione a fini pubblicitari e la personalizzazione restano disattivate.

Con il consenso alle attività di marketing, Meta riceve gli eventi PageView su pagine di presentazione pubbliche selezionate, l'URL della pagina e le informazioni di rete/browser, al fine di misurare l'efficacia pubblicitaria. PageView esclude le pagine di CV, ricerca di lavoro, account e pagamenti. Il matching automatico e la raccolta automatica degli eventi sono disattivati. Meta potrebbe elaborare queste informazioni al di fuori del tuo paese. Il rifiuto non limita l'uso degli strumenti.

Con consenso marketing, Google Ads misura account verificati e acquisti confermati tramite ID anonimo e importo/valuta. Nessun CV o dato di contatto.

Con consenso marketing, Meta può memorizzare gli identificatori dei clic pubblicitari nella pagina di registrazione per attribuire un account verificato successivo. Aprire il modulo non conta come registrazione.

Con consenso marketing, Meta misura anche gli account verificati nella pagina iniziale dello spazio di lavoro tramite un ID anonimo. Nessun CV o dato di contatto.

La tua scelta viene memorizzata per 180 giorni. Puoi modificarla o revocarla in qualsiasi momento tramite le Impostazioni cookie. Il rifiuto dei cookie di analisi non limita gli strumenti di carriera.

Informativa sui cookie