roTEAMnet

Master Thesis Scatter Estimation in Computed Tomography

Elekta Instrument AB · Stockholm, Sweden

Full-time

Solo formulazione originale; questo è indipendente dall'idoneità professionale. Il lavoro da remoto non implica automaticamente l'idoneità a livello globale o orari flessibili.

Fonte originale: Workday · Pubblicato 2026-10-22 · Ultimo controllo 2026-11-25 10:53 UTC

Modalità di lavoro non specificataLivello non specificatoTempo pienoElekta Instrument AB Svezia

Verifica i requisiti rispetto alla tua esperienza, prepara il documento e conserva l'opportunità nelle tue candidature. Invierai tu stesso la candidatura.

Are you a current Elekta employee?

Please click here to apply through our internal career site Find Jobs - Elekta.

We don’t just build technology. We build hope for everyone dealing with Cancer.

Elekta is shaping the standard of care, together with healthcare providers, by developing precision radiation medicine that brings advanced radiotherapy into routine clinical practice. Our solutions support consistent, efficient and personalized care, addressing evolving patient needs. Through adaptive radiotherapy, precision treatment delivery and integrated workflows, Elekta supports care teams across a range of clinical settings. Each year more than 2 million patients are treated using Elekta solutions across over 130 countries. Elekta is headquartered in Stockholm, Sweden, with over 4,000 employees and offices in more than 40 countries. The company is listed on Nasdaq Stockholm. For more information, visit elekta.com.

Introduction

Cone beam computed tomography (CBCT) is a method of forming a 3D image from a set of X-ray projections. The projections are formed by exposing a subject to a cone-shaped X-ray beam and capturing the photons in a flat-panel detector, similar to the detector of a camera. The subject both attenuates and scatters the X-ray beam, affecting what photons are detected by the detector. Projections are formed from multiple directions. This results in an inverse problem that can be solved to reconstruct a 3D image of the subject.

There are efficient algorithms to solve this inverse problem when there is no scattering (FDK or iterative solvers). A common approach to CBCT reconstruction is to estimate the scattering and effectively subtract it from projection images so that these efficient algorithms can be employed for reconstruction.

Background

At Elekta, we develop products for cancer radiotherapy that use CBCT for imaging and positioning the patient. We are today using an AI model to estimate the scatter component in CBCT images. As an alternative to this, we have developed a physics-based algorithm (patent pending) for estimating scatter. We have made a prototype implementation of this algorithm in 2000 lines of Rust that we call Rainbow.

Problem Statement

There are several open questions related to our scatter estimates that could be the basis of a master's thesis. What we decide on depends on your interests and our needs.

Engineering focus: How do we best evaluate Rainbow’s performance? What subjects do we scan, what metrics do we measure, how do we compare with state-of-the-art AI models? What applications is it suitable for?

Physics focus: What improvements can be made to the physical model of Rainbow? We have made several approximations of the scattering and detector physics that can be improved for a more accurate model. This may involve both physics theory and experimental work in our labs.

Implementation focus: To be clinically useful, Rainbow needs to run faster. Are there optimizations we can make to the current implementation? How do we efficiently implement this algorithm on a GPU?

Math focus: What improvements can be made to the algorithm, such as Monte Carlo variance reduction or methods for accelerating convergence of a numerical solver.

Depending on our findings until the start of the master thesis work, we may have other topics related to CBCT reconstruction and scatter estimates.

Output

The student is expected to write a report that helps us understand the above-mentioned aspects of Rainbow. In the case of investigating various improvements, this should be accompanied by code contributions to Rainbow. In the case of benchmarking Rainbow, the report should be accompanied by scripts for running these benchmarks.

Who are we looking for?

Preferred Masters education: Physics or Mathematics

Required skills: Python programming, good understanding of statistics and numerical methods.

Useful skills: X-ray lab work, Rust programming, GPU computing, Monte Carlo simulations

Practicalities

Location: Forskaren, Hagaplan 4, Stockholm

Supervisor: Petter Säterskog, petter.saterskog@elekta.com

Start date: Fall 2026 or early spring 2027
Candidati sul sito web originale

Workday

Candidati con un account gratuito

Un account gratuito mostra il link di candidatura originale agli utenti idonei, valuta la tua affinità con l'offerta, la salva nel tuo tracker e consente ad Autopilot di trovare altre offerte simili.

Crea account Accedi

I cookie essenziali supportano la sessione e la sicurezza. Google Analytics e la misurazione pubblicitaria di Meta vengono caricati solo previo consenso specifico. Il testo del CV e i dati di contatto non vengono inviati.

Cookie essenziali · sempre attivi

Sessione, protezione CSRF e preferenze sui cookie. Questi elementi supportano l'accesso all'account e la scelta effettuata in questa sede.

Google Analytics misura le pagine pubbliche e le azioni predefinite previo consenso. Il testo di ricerca, il contenuto del CV, gli ID account e i token di pagamento sono esclusi. L'archiviazione a fini pubblicitari e la personalizzazione restano disattivate.

Con il consenso alle attività di marketing, Meta riceve gli eventi PageView su pagine di presentazione pubbliche selezionate, l'URL della pagina e le informazioni di rete/browser, al fine di misurare l'efficacia pubblicitaria. PageView esclude le pagine di CV, ricerca di lavoro, account e pagamenti. Il matching automatico e la raccolta automatica degli eventi sono disattivati. Meta potrebbe elaborare queste informazioni al di fuori del tuo paese. Il rifiuto non limita l'uso degli strumenti.

Con consenso marketing, Google Ads misura account verificati e acquisti confermati tramite ID anonimo e importo/valuta. Nessun CV o dato di contatto.

Con consenso marketing, Meta può memorizzare gli identificatori dei clic pubblicitari nella pagina di registrazione per attribuire un account verificato successivo. Aprire il modulo non conta come registrazione.

Con consenso marketing, Meta misura anche gli account verificati nella pagina iniziale dello spazio di lavoro tramite un ID anonimo. Nessun CV o dato di contatto.

La tua scelta viene memorizzata per 180 giorni. Puoi modificarla o revocarla in qualsiasi momento tramite le Impostazioni cookie. Il rifiuto dei cookie di analisi non limita gli strumenti di carriera.

Informativa sui cookie