Mentions de la source, distinctes de l’adéquation professionnelle. Remote ne signifie pas automatiquement accès mondial ou horaires flexibles.
Source originale: Workable · Publiée le 2026-09-09 · Dernière vérification 2026-11-24 02:52 UTC
Postuler sur le site d’origine Vérifier mon profil Adapter mon CV
Connectez-vous pour enregistrer l’offre
Comparez les exigences à votre expérience, préparez votre document et suivez l’offre. Vous envoyez vous-même la candidature.
No of Position:01
Job Summary
We are seeking an EMI/EMC Test Engineer to own electromagnetic compatibility and electromagnetic interference testing for our medical device portfolio, ensuring compliance with IEC 60601-1-2 and supporting FDA/international regulatory submissions. The role works closely with R&D, systems engineering, and regulatory affairs to identify and mitigate EMC risks throughout the design lifecycle, particularly for devices operating in clinical and home-use environments.
Required Qualifications
Bachelor's degree in Electrical/Biomedical Engineering or related field
3–7 years of EMI/EMC experience, with at least 2+ years specific to medical devices
Working knowledge of IEC 60601-1-2 and its test methods (IEC 61000-4 series as applied to medical devices)
Understanding of "essential performance" and "basic safety" concepts as they relate to EMC pass/fail criteria
Experience with EMC test equipment: EMI receivers, spectrum analyzers, ESD guns, surge/EFT/burst generators, near-field probes
Ability to read schematics/PCB layouts, particularly isolation barriers and patient-applied parts
Strong technical writing skills for regulatory-grade documentation
Key Responsibilities
Plan, execute, and analyze EMC pre-compliance and full-compliance testing per IEC 60601-1-2 (radiated/conducted emissions, radiated/conducted immunity, ESD, EFT/burst, surge, magnetic field immunity, dips & interruptions)
Apply collateral/particular standards as applicable (e.g., IEC 60601-1-11 for home healthcare environments, IEC 60601-2-XX device-specific standards)
Support wireless coexistence testing for connected medical devices (BLE, Wi-Fi) per FDA guidance on RF wireless technology
Conduct EMC design reviews at schematic, PCB layout, cable/harness, and enclosure stages — especially around patient-connected circuits and isolation boundaries
Debug EMI/EMC failures using spectrum analyzers, EMI receivers, near-field probes, ESD simulators, and surge/EFT generators
Coordinate with accredited third-party test labs (e.g., UL, TÜV, Intertek) for formal IEC 60601-1-2 certification testing
Author and maintain EMC test plans, protocols, and reports suitable for FDA 510(k)/PMA submissions and CE technical files (MDR)
Link EMC test results to risk management file (ISO 14971) — document hazards, mitigations, and residual risk related to electromagnetic disturbances
Recommend and validate design mitigations (shielding, filtering, grounding, isolation) without compromising patient safety or essential performance
Support root-cause investigation for field complaints or CAPAs related to EMC issues
Maintain traceability between EMC test evidence and Design History File (DHF) per IEC 62304/design control requirements
Track evolving global regulatory requirements (FDA, EU MDR, Health Canada, etc.) affecting EMC for medical devices
Postuler sur le site d’origine Job Summary
We are seeking an EMI/EMC Test Engineer to own electromagnetic compatibility and electromagnetic interference testing for our medical device portfolio, ensuring compliance with IEC 60601-1-2 and supporting FDA/international regulatory submissions. The role works closely with R&D, systems engineering, and regulatory affairs to identify and mitigate EMC risks throughout the design lifecycle, particularly for devices operating in clinical and home-use environments.
Required Qualifications
Bachelor's degree in Electrical/Biomedical Engineering or related field
3–7 years of EMI/EMC experience, with at least 2+ years specific to medical devices
Working knowledge of IEC 60601-1-2 and its test methods (IEC 61000-4 series as applied to medical devices)
Understanding of "essential performance" and "basic safety" concepts as they relate to EMC pass/fail criteria
Experience with EMC test equipment: EMI receivers, spectrum analyzers, ESD guns, surge/EFT/burst generators, near-field probes
Ability to read schematics/PCB layouts, particularly isolation barriers and patient-applied parts
Strong technical writing skills for regulatory-grade documentation
Key Responsibilities
Plan, execute, and analyze EMC pre-compliance and full-compliance testing per IEC 60601-1-2 (radiated/conducted emissions, radiated/conducted immunity, ESD, EFT/burst, surge, magnetic field immunity, dips & interruptions)
Apply collateral/particular standards as applicable (e.g., IEC 60601-1-11 for home healthcare environments, IEC 60601-2-XX device-specific standards)
Support wireless coexistence testing for connected medical devices (BLE, Wi-Fi) per FDA guidance on RF wireless technology
Conduct EMC design reviews at schematic, PCB layout, cable/harness, and enclosure stages — especially around patient-connected circuits and isolation boundaries
Debug EMI/EMC failures using spectrum analyzers, EMI receivers, near-field probes, ESD simulators, and surge/EFT generators
Coordinate with accredited third-party test labs (e.g., UL, TÜV, Intertek) for formal IEC 60601-1-2 certification testing
Author and maintain EMC test plans, protocols, and reports suitable for FDA 510(k)/PMA submissions and CE technical files (MDR)
Link EMC test results to risk management file (ISO 14971) — document hazards, mitigations, and residual risk related to electromagnetic disturbances
Recommend and validate design mitigations (shielding, filtering, grounding, isolation) without compromising patient safety or essential performance
Support root-cause investigation for field complaints or CAPAs related to EMC issues
Maintain traceability between EMC test evidence and Design History File (DHF) per IEC 62304/design control requirements
Track evolving global regulatory requirements (FDA, EU MDR, Health Canada, etc.) affecting EMC for medical devices
Workable
Postulez avec un compte gratuit
Créer un compte Se connecterUn compte gratuit vérifie votre adéquation, enregistre l’offre dans votre suivi et laisse le pilote trouver des offres similaires. Les membres éligibles voient le lien de candidature d’origine.