roTEAMnet

Lead Engineer - Secondary

RE1055 GE Renewable Energy Technologies Private Limited · Noida, India

Temps plein

Mentions de la source, distinctes de l’adéquation professionnelle. Remote ne signifie pas automatiquement accès mondial ou horaires flexibles.

Source originale: Workday · Publiée le 2026-11-20 · Dernière vérification 2026-11-25 16:57 UTC

Mode de travail non préciséLead / expert1+ ansIngénierie & R&D techniqueTemps pleinRE1055 GE Renewable Energy Technologies Private Limited Inde

Comparez les exigences à votre expérience, préparez votre document et suivez l’offre. Vous envoyez vous-même la candidature.

Job Description Summary
As a Lead Engineer – Control & Protection at GE Vernova Grid Solutions, you will play a crucial role in designing, implementing, and optimizing protection relay systems for EHV/HV substations considering the safety/quality/Cost/time delivery criteria. Your expertise will ensure the reliability and efficiency of power systems, supporting our global operations across various regions.
This role involves in leading the secondary engineering activities (Control & Protection, Substation Automation Systems, Interface Engineering, Telecom Requirements & LV Auxiliary Systems for EHV/HV Electrical Substations (AIS / GIS / HVDC / FACTS / STATCOM / Onshore / Offshore / Renewable/etc.,)
The candidate shall execute with association of workgroups, where applicable, in order to meet assigned objectives. In this role, the candidate will work within defined parameters to draw conclusions, apply concepts to issues of moderate complexity, and resolve issues through immediate action or short-term planning. The candidate will work with GSI Global Engineering Center (GSI GEC) to coordinate with the GSI Regions / Business Lines / as per Project requirement.

Job Description

Roles and Responsibilities

Specific Role Requirements:

Design and prepare Engineering drawings (SLD/KLD/PSLD/CRP) as per project requirement in anyone of E-CAD Tool (Ex. Engineering Base software/E-Plan/ AutoCAD Electrical/equivalent) for up to 400/765kV Substations.

Design/Review the Substation automation system based on IEC61850 & interconnections.

Review BOQ and Network drawings of PLCC/FOTE engineering and need to interface between CRP & SAS with Telecom Equipment.

Review equipment drawings of major Substation Equipment for AIS / GIS like Circuit breakers, Isolators, Earth switches, CSD, PDM, Transformers/Reactors & associated Conditional Monitoring Devices etc.,

Perform CT and VT and its sizing calculations.

Design and Review the control/Power cable engineering in substations.

Design the LV/LT auxiliary systems for Electrical Substations and interface with the SAS/SCADA.

Perform/review the protection relay application / setting calculations and coordination including tripping analysis.

Add-on Competency (Optional)

Renewable project engg i.e. Solar, On-shore / Off-shore Wind, Battery Storage or hybrid.

HVDC/FACTS integrated project applications.

Perform/Review the study on Electrical Power systems and load flow and short circuit studies etc.,

Competency on specialized tools like CANECO, ETAP, DIG Silent or equivalent

Working experience in SAS, Database Preparation in the automation/RTU software

Review / consolidate the IO Mapping with respect to the scheme drawings/troubleshoot of database issues in SAS system / RTU based system.

Able to work with different make IEDs, Numerical protection relays and BCUs.

Required Qualifications

Bachelor’s degree/Diploma in electrical engineering or related field, from an accredited college or university.
Minimum of 12+ years of experience with Degree or 10+ years with Diploma in EHV/ HV AIS & GIS Substation design

Experience in EPC (Engineering, Procurement, Construction) environments with multidisciplinary teams.

Experience of Secondary(CRP/SAS, Aux Systems, Telecom, Interface) engineering up to 765kV/400kV/220KV and HVDC Substations (AIS/GIS/SOLAR/WIND).

Experience/Knowledge on Relay Testing, Equipment Testing, Control / Protection scheme testing & SAS Commissioning experience (min 1 year) shall be given additional weightage.

Desired Characteristics

Strong oral and written communication skills. Strong interpersonal, responsive and supervision skills. Demonstrated ability to evaluate and resolve problems. Demonstrated ability to manage programs / projects. Ability to document, plan, market, and execute programs. Established project management skills.

Fluent in English; additional language (any foreign Language) is a plus.

Willingness to travel internationally as required.

Proven technical leadership in a complex system engineering development environment.

Proactively serves on cross functional leadership teams; self-directed decision-making; Pulls in experts when needed.

Key Competences

Technical Expertise: In-depth understanding of substation protection systems, relay technologies, relay tripping philosophies, substation automation systems, Interface Engineering, LV Auxiliary Systems & Telecom Panels.

Project Management: Ability to manage multiple projects, prioritize tasks, and meet deadlines.

Communication: Excellent verbal and written communication skills for effective customer and team interactions.

Strong leadership, supportive and team coordination abilities to guide and mentor junior engineers.

Problem-Solving: Proficient in identifying issues and implementing effective solutions.

Quality Focus: Commitment to maintaining high standards of quality and compliance.

Additional Information

Relocation Assistance Provided: Yes
Postuler sur le site d’origine

Workday

Postulez avec un compte gratuit

Un compte gratuit vérifie votre adéquation, enregistre l’offre dans votre suivi et laisse le pilote trouver des offres similaires. Les membres éligibles voient le lien de candidature d’origine.

Créer un compte Se connecter

Les cookies essentiels assurent la session et la sécurité. Google Analytics et la mesure publicitaire Meta se chargent selon vos choix séparés. Aucun CV ni coordonnées ne sont transmis.

Cookies essentiels · toujours actifs

Session, protection CSRF et choix des cookies permettent l’accès au compte et mémorisent votre décision.

Google Analytics mesure les pages publiques et des actions prédéfinies après accord. Recherches, CV, identifiants de compte et jetons de paiement sont exclus. Stockage publicitaire et personnalisation restent désactivés.

Avec votre accord marketing, Meta reçoit PageView sur certaines pages publiques de présentation, l’URL et des informations réseau/navigateur pour mesurer les publicités. PageView exclut les pages CV, recherche d’emploi, compte et paiements. Rapprochement et événements automatiques sont désactivés. Un traitement hors de votre pays est possible. Refuser ne limite pas les outils.

Avec votre consentement marketing, Google Ads mesure les comptes vérifiés et achats confirmés avec un identifiant anonyme et le montant/la devise. Aucun CV ni coordonnées.

Avec votre consentement marketing, Meta peut conserver les identifiants de clic publicitaire sur la page d’inscription pour attribuer un compte vérifié ultérieur. Ouvrir le formulaire ne compte pas comme une inscription.

Avec votre consentement marketing, Meta mesure aussi la création de compte vérifié sur l’accueil de votre espace avec un identifiant anonyme. Aucun CV ni coordonnées.

Votre choix est conservé 180 jours. Modifiez-le ou retirez-le à tout moment dans les réglages. Refuser la mesure ne limite pas les outils.

Politique de cookies