roTEAMnet

Master Thesis Motion Compensation in CBCT-imaging

Elekta Instrument AB · Stockholm, Sweden

Temps plein

Mentions de la source, distinctes de l’adéquation professionnelle. Remote ne signifie pas automatiquement accès mondial ou horaires flexibles.

Source originale: Workday · Publiée le 2026-10-22 · Dernière vérification 2026-11-25 10:53 UTC

Mode de travail non préciséNiveau non préciséGestionnaire paie & rémunérationTemps pleinElekta Instrument AB Suède

Comparez les exigences à votre expérience, préparez votre document et suivez l’offre. Vous envoyez vous-même la candidature.

Are you a current Elekta employee?

Please click here to apply through our internal career site Find Jobs - Elekta.

We don’t just build technology. We build hope for everyone dealing with Cancer.

Elekta is shaping the standard of care, together with healthcare providers, by developing precision radiation medicine that brings advanced radiotherapy into routine clinical practice. Our solutions support consistent, efficient and personalized care, addressing evolving patient needs. Through adaptive radiotherapy, precision treatment delivery and integrated workflows, Elekta supports care teams across a range of clinical settings. Each year more than 2 million patients are treated using Elekta solutions across over 130 countries. Elekta is headquartered in Stockholm, Sweden, with over 4,000 employees and offices in more than 40 countries. The company is listed on Nasdaq Stockholm. For more information, visit elekta.com.

1 Introduction

Cone-beam CT (CBCT) is an imaging technique widely used in radiation therapy for patient positioning and adaptive workflow. 2D projections are acquired from a cone-shaped X-ray beam rotating around the patient, and a 3D image is reconstructed from these projections. The imaging device is mounted directly on the treatment machine, i.e. a linear accelerator (linac), which allows for imaging the patient in the treatment position. However, the acquisition of CBCT images is relatively slow, and patient motion during the scan can lead to image artifacts and reduced image quality. Motion compensation techniques aim to mitigate these effects by estimating and correcting for patient motion during the reconstruction process. This thesis will investigate and prototype motion compensation methods for CBCT imaging in radiation therapy, with the goal of improving image quality and treatment accuracy.

2 Background

Respiratory and cardiac motion are the dominant source of motion artifacts in CBCT for radio[1]therapy which cause blurring, streaking and banding artifacts in the reconstructed images (Chen et al., 2004). Currently deployed techniques to mitigate motion artifacts in CBCT include:

1. Breath-hold techniques — The patient suspends respiration during acquisition, ef[1]fectively eliminating motion. However, this approach has significant clinical overhead: it reduces patient comfort, requires trained operator coordination, and is impossible for uncooperative or sedated patients.

2. Respiratory gating (Kincaid Jr. et al., 2013) — Only projections acquired during a narrow phase window of the breathing cycle are used for reconstruction. This eliminates motion blur but reduces the effective number of projections by 80–90%, resulting in severe undersampling, pronounced streaking artifacts, and degraded soft-tissue contrast. Scan time and/or imaging dose must be increased to compensate.

3. Phase-sorted 4D-CBCT (Sonke et al., 2005) — Projections are binned into typically 8–10 motion phases using a respiratory surrogate signal (e.g., external fiducial marker), and each bin is reconstructed independently, yielding a time-resolved series of 3D volumes. This preserves the full acquired dataset but divides projections among bins, creating the same undersampling penalties as gating.

Each of the above techniques has its own limitations and/or disadvantages, and there is a need for more efficient methods. Recent research has explored advanced algorithms, such as deformable image registration and machine learning-based approaches (Amirian et al., 2024), to improve motion estimation in medical imaging. This thesis will build upon these advancements to develop a novel motion compensation algorithm that can be integrated into our CBCT reconstruction pipeline.

3 Purpose and Aim of the Thesis

The purpose of this thesis is to investigate and prototype motion compensation methods for CBCT imaging in radiation therapy. The aim is to develop a motion compensation algorithm that can effectively mitigate the effects of patient motion, particularly respiratory motion, while maintaining image quality, computational efficiency and minimizing the acquisition time and delivered dose to the patient. The thesis will involve a comprehensive literature review, algo[1]rithm development, and performance evaluation, with the goal of improving image quality and treatment accuracy in CBCT imaging for radiation therapy.

1. Research Question: How can we develop and implement a motion compensation al[1]gorithm for CBCT imaging that effectively mitigates the effects of patient motion, par[1]ticularly respiratory motion and still limit the acquisition time and delivered dose to the patient?

2. Objectives:

(a) Conduct a comprehensive literature review on existing motion compensation techniques in CBCT imaging.

(b) Develop, or adapt1, a motion compensation algorithm that can be integrated into the CBCT reconstruction pipeline.

(c) Evaluate the performance of the developed algorithm in terms of image quality, computational efficiency, and robustness.

(d) Compare the proposed algorithm with existing methods to assess its advantages and limitations.

(e) Document the methodology, results, and conclusions in a comprehensive report, and provide the source code for the developed algorithm.

4 Output

The expected output of this thesis will be a prototype implementation of a motion compensation algorithm that can be integrated into our CBCT-image reconstruction pipeline. The student will be responsible for developing and testing the algorithm, as well as evaluating its performance in terms of image quality and computational efficiency. The final deliverables will include a comprehensive report detailing the methodology, results, and conclusions, as well as the source code for the developed algorithm.

5 Who are we looking for?

The ideal candidate for this thesis project should have a strong background in physics, medical imaging, and machine learning. Preferred qualifications include experience with programming languages such as Python and familiarity with image processing libraries and frameworks. The student should be motivated, detail-oriented, and capable of working independently as well as collaboratively in a research environment. The project includes a literature study, algorithm development, and performance evaluation, so the student should be comfortable with both theoretical and practical aspects of research.

6 Practicalities

• Location: Elekta AB, Stockholm, Sweden

• Supervisor: Niklas Gunnarsson (niklas.gunnarsson@elekta.com)

• Start date: Spring 2027, exact date to be agreed upon.

References

Amirian, M., Barco, D., Herzig, I., & Schilling, F.-P. (2024). Artifact reduction in 3D and 4D cone-beam computed tomography images with deep learning: A review. IEEE Access, 12, 10281–10295. https://doi.org/10.1109/ACCESS.2024.3353195

Chen, G. T., Kung, J. H., & Beaudette, K. P. (2004). Artifacts in computed tomography scan[1]ning of moving objects. Seminars in Radiation Oncology, 14 (1), 19–26. https://doi.org/https://doi.org/10.1053/j.semradonc.2003.10.004

Kincaid Jr., R. E., Yorke, E. D., Goodman, K. A., Rimner, A., Wu, A. J., & Mageras, G. S. (2013). Investigation of gated cone-beam CT to reduce respiratory motion blurring. Medical Physics, 40 (4), 041717. https://doi.org/https://doi.org/10.1118/1.4795336

Sonke, J.-J., Zijp, L., Remeijer, P., & van Herk, M. (2005). Respiratory correlated cone beam CT. Medical Physics, 32 (4), 1176–1186. https://doi.org/https://doi.org/10.1118/1.1869074
Postuler sur le site d’origine

Workday

Postulez avec un compte gratuit

Un compte gratuit vérifie votre adéquation, enregistre l’offre dans votre suivi et laisse le pilote trouver des offres similaires. Les membres éligibles voient le lien de candidature d’origine.

Créer un compte Se connecter

Les cookies essentiels assurent la session et la sécurité. Google Analytics et la mesure publicitaire Meta se chargent selon vos choix séparés. Aucun CV ni coordonnées ne sont transmis.

Cookies essentiels · toujours actifs

Session, protection CSRF et choix des cookies permettent l’accès au compte et mémorisent votre décision.

Google Analytics mesure les pages publiques et des actions prédéfinies après accord. Recherches, CV, identifiants de compte et jetons de paiement sont exclus. Stockage publicitaire et personnalisation restent désactivés.

Avec votre accord marketing, Meta reçoit PageView sur certaines pages publiques de présentation, l’URL et des informations réseau/navigateur pour mesurer les publicités. PageView exclut les pages CV, recherche d’emploi, compte et paiements. Rapprochement et événements automatiques sont désactivés. Un traitement hors de votre pays est possible. Refuser ne limite pas les outils.

Avec votre consentement marketing, Google Ads mesure les comptes vérifiés et achats confirmés avec un identifiant anonyme et le montant/la devise. Aucun CV ni coordonnées.

Avec votre consentement marketing, Meta peut conserver les identifiants de clic publicitaire sur la page d’inscription pour attribuer un compte vérifié ultérieur. Ouvrir le formulaire ne compte pas comme une inscription.

Avec votre consentement marketing, Meta mesure aussi la création de compte vérifié sur l’accueil de votre espace avec un identifiant anonyme. Aucun CV ni coordonnées.

Votre choix est conservé 180 jours. Modifiez-le ou retirez-le à tout moment dans les réglages. Refuser la mesure ne limite pas les outils.

Politique de cookies