roTEAMnet

Master Thesis Creating Synthetic Motion in MR Images for Evaluation of Novel Approaches to Motion Management on Unity

Elekta Instrument AB · Stockholm, Sweden

Temps plein

Mentions de la source, distinctes de l’adéquation professionnelle. Remote ne signifie pas automatiquement accès mondial ou horaires flexibles.

Source originale: Workday · Publiée le 2026-10-22 · Dernière vérification 2026-11-25 10:53 UTC

Mode de travail non préciséNiveau non préciséDéveloppeur jeux & 3DTemps pleinElekta Instrument AB Suède

Comparez les exigences à votre expérience, préparez votre document et suivez l’offre. Vous envoyez vous-même la candidature.

Are you a current Elekta employee?

Please click here to apply through our internal career site Find Jobs - Elekta.

We don’t just build technology. We build hope for everyone dealing with Cancer.

Elekta is shaping the standard of care, together with healthcare providers, by developing precision radiation medicine that brings advanced radiotherapy into routine clinical practice. Our solutions support consistent, efficient and personalized care, addressing evolving patient needs. Through adaptive radiotherapy, precision treatment delivery and integrated workflows, Elekta supports care teams across a range of clinical settings. Each year more than 2 million patients are treated using Elekta solutions across over 130 countries. Elekta is headquartered in Stockholm, Sweden, with over 4,000 employees and offices in more than 40 countries. The company is listed on Nasdaq Stockholm. For more information, visit elekta.com.

Introduction

Radiotherapy targets and surrounding anatomy can move during treatment. The Elekta Unity combines an MR scanner with a linear accelerator, permitting anatomy to be visualised during radiation delivery, and enabling correction based on live information.

This project will investigate how synthetic MR image data can be used to accelerate the development and evaluation of motion-management technologies on the Elekta Unity. The student will generate anatomically plausible motion within MR images, create realistic Unity-like cine datasets with known ground truth, and develop quantitative methods for assessing tracking accuracy. The resulting framework will provide a reusable platform for benchmarking current and future motion-tracking algorithms. 

Background

A radiotherapy treatment is designed with millimeter precision to ensure that high doses of radiation can be delivered to the target, whilst avoiding critical anatomic structures. However, both the target and the surrounding anatomy may move during treatment, due to a range of physiological processes such as respiration, peristalsis, and organ drift. The Elekta Unity can visualize and respond to this motion in real-time, increasing dosimetric accuracy, and thus improving patient outcomes.

The current Automatic Position Management (APM) framework acquires an orthogonal pair of 2D cine images at a rate of 5 Hz. Each image is compared to a reference using rigid registration to estimate target motion from cine MR images. This method is challenged in cases where there is deformation of anatomy or so called “through-plane motion” i.e. anatomical motion normal to the imaging plane.

It may be possible to improve the performance of APM, i.e. by accounting for deformable motion or by modifying the imaging planes. However, it is not possible to verify these improvements without a reliable ground truth. Therefore, we propose creating a series of 3D images with anatomically plausible motion and extracting 2D images from them. This will allow algorithms to be tested on the 2D images and compared to a 3D ground truth.

Problem Statement

The project will address three linked problems: 

Generate paired 3D and 2D MR image datasets containing artificial but anatomically plausible motion. Pretreatment MR images will be transformed using plausible deformation vector fields, and synthetic sagittal and coronal cine images will be generated with characteristics representative of Unity acquisitions.

Establish baseline performance for the current APM algorithm. The synthetic cine images will be processed using the Motion Management Replay Tool (MMRP), with quantitative metrics defined for displacement accuracy and known failure modes including jitter, through-plane motion and anatomical deformation.

Explore one or more approaches for improving target tracking performance, for example by incorporating deformable motion information into the tracking process.

Output

A synthetic dataset of paired 3D MR images and Unity-like 2D cine images for future testing. 

A defined set of quantitative evaluation metrics and a baseline measurement of current APM tracking accuracy. 

A preliminary evaluation of alternative tracking approaches incorporating deformable motion information.

Prototype scripts and reproducible processing pipelines. 

A written student report and final presentation. 

Who are we looking for?

We are looking for a master’s student in medical physics, computer science, applied mathematics, engineering physics, or a related scientific discipline. 

Required profile: 

Programming experience and the ability to work independently on an exploratory research problem. 

A strong scientific or engineering background, including confidence with quantitative analysis. 

Desirable experience: 

Experience in medical image processing, ideally in Python

Familiarity with radiotherapy, especially the MR-Linac

Practicalities

Location: Elekta office, Stockholm

Supervisor: Ned Goodwin

Start date: Flexible
Postuler sur le site d’origine

Workday

Postulez avec un compte gratuit

Un compte gratuit vérifie votre adéquation, enregistre l’offre dans votre suivi et laisse le pilote trouver des offres similaires. Les membres éligibles voient le lien de candidature d’origine.

Créer un compte Se connecter

Les cookies essentiels assurent la session et la sécurité. Google Analytics et la mesure publicitaire Meta se chargent selon vos choix séparés. Aucun CV ni coordonnées ne sont transmis.

Cookies essentiels · toujours actifs

Session, protection CSRF et choix des cookies permettent l’accès au compte et mémorisent votre décision.

Google Analytics mesure les pages publiques et des actions prédéfinies après accord. Recherches, CV, identifiants de compte et jetons de paiement sont exclus. Stockage publicitaire et personnalisation restent désactivés.

Avec votre accord marketing, Meta reçoit PageView sur certaines pages publiques de présentation, l’URL et des informations réseau/navigateur pour mesurer les publicités. PageView exclut les pages CV, recherche d’emploi, compte et paiements. Rapprochement et événements automatiques sont désactivés. Un traitement hors de votre pays est possible. Refuser ne limite pas les outils.

Avec votre consentement marketing, Google Ads mesure les comptes vérifiés et achats confirmés avec un identifiant anonyme et le montant/la devise. Aucun CV ni coordonnées.

Avec votre consentement marketing, Meta peut conserver les identifiants de clic publicitaire sur la page d’inscription pour attribuer un compte vérifié ultérieur. Ouvrir le formulaire ne compte pas comme une inscription.

Avec votre consentement marketing, Meta mesure aussi la création de compte vérifié sur l’accueil de votre espace avec un identifiant anonyme. Aucun CV ni coordonnées.

Votre choix est conservé 180 jours. Modifiez-le ou retirez-le à tout moment dans les réglages. Refuser la mesure ne limite pas les outils.

Politique de cookies