About Fluidstack

We exist to make humanity more free. For most of human history, you farmed or you starved. Technology gave people more time for the things they wanted to do, instead of things they had to do. Powerful AI will be the biggest lever for human choice we've ever built - but only if models are aligned with what humanity actually wants. There are groups building AI who don't share these goals. Whoever deploys frontier compute infrastructure fastest will decide whether AI expands human freedom or shrinks it.

We're singularly focused on delivering 10 to 100s of GWs of compute faster than anyone else, rethinking every layer of the stack. We acquire power, design and build data centers, and operate them - with teams spanning hardware and software. Speed and scale are our key differentiators. Come be a part of building civilization-scale infrastructure for AI.

We hire people who care deeply about this problem space. If that is you, please apply!

How We Operate

Be a barrel. Full autonomy. Own things end to end, take on scope without being asked, no permission required to operate outside your core role.

Insane urgency. We drive everything forward as fast as possible.

Reason from first principles. Challenge every assumption. Zero analogy thinking, no egos, the best idea wins.

Love of the game. The frontier of AI is the most interesting problem of our time. We put in long hours at high intensity to push the frontier forward.

Build something that actually matters. If you're going to spend your time, spend it on something that matters to the world.

The Power Generation Team

The Power Generation team designs and builds the power that runs Fluidstack's AI infrastructure, including grids that stand alone with no utility behind them.

Examples of key problems the team is working on

Build an islanded grid at gigawatt scale, from a blank sheet. Generation, storage and compute running with no utility behind them, where the machine you design is the only thing holding voltage. No playbook exists at this size, so the architecture you set becomes the reference.

Get power online in months, not years. Interconnection queues are measured in years and we do not have them. Generating our own power is how a site goes from signed lease to live compute inside six months, and the power system is the long pole in that plan.

Make one power block, then build it a thousand times. A repeatable block and cluster unit, validated once and stamped across the fleet, is the only route to the scale we are targeting. Every bespoke site is schedule we do not get back.

Design a grid whose largest load answers back. Compute is not passive demand here. Load behaviour, curtailment and shedding are design variables you negotiate and specify, a lever almost no power system engineer has ever been handed.

Role Scope

Design the MV network. Design the medium-voltage network that carries power from each generation block to the data halls, inside the system design basis, as one standard that every site deploys and that grows by adding blocks rather than by redesign.

Design the cluster tie and MV substations. Cover bus arrangement, transformer selection, tie and transfer schemes, and the switching sequences that let a new block energize next to live ones without an outage.

Run the network studies yourself. Size feeders, cable and transformers to the load and produce the load flow, voltage drop, short circuit, protection coordination, and EMT studies of switching, energization and islanded transients behind them, as models that rerun for each site's layout and block count.

Set protection and specifications. Set the protection philosophy and relay settings for an inverter-dominated network with limited fault current, and write the standard specifications for MV switchgear, transformers, cable and relaying that ship with every block.

Define the envelope. State the block count, feeder length, fault level and load step the standard holds for, set the triggers that send a site to a site-specific study, and fold what each energized site teaches back into the next revision.

What We're Looking For

The below is a starting point. We always make space for exceptional people, so if you don't fit this role exactly, tell us where you would.

10+ years of experience in medium-voltage power distribution design, including network studies, protection coordination, and MV switchgear and substation design.

You've personally built power system models of an MV network and produced the load flow, short circuit and cable sizing results that went into issued-for-construction drawings.

You've built electromagnetic transient (EMT) models of switching, energization or islanded events, such as transformer inrush, ferroresonance or inverter-dominated fault response, and changed a design because of what they showed.

You've set the protection philosophy and relay settings for a system with limited or variable fault current, and you can walk through the coordination that proved it.

You've designed MV distribution down to the hardware, including metal-clad switchgear, transformers, cable and duct bank ampacity, and grounding, and defended those choices against NEC, NFPA 70E and IEEE requirements with engineers of record and AHJs.

You've designed an MV substation or bus tie scheme that let new capacity energize next to live load, and written the switching sequence the operators followed.

You've turned a one-off design into a standard that other engineers applied across multiple projects, and written its design basis clearly enough that they could use it without calling you.

You're comfortable with regular travel: expect 25% or more, depending on business needs.

Most of our engineering team, stakeholders, and work are based in Austin, TX, and we value working in person. We have a strong preference for Austin and run a hybrid model, but we're open to other locations for the right role and candidate.

Bonus: Transmission-side study and protection work, including interconnection and EMT studies. Grid-forming and islanded systems. A Professional Engineer licence.

We are committed to pay equity and transparency.

Fluidstack is an Equal Employment Opportunity Employer. All qualified applicants will receive consideration for employment without regard to race, color, religion, sex, national origin, sexual orientation, gender identity, disability and protected veterans’ status, or any other characteristic protected by law. Fluidstack will consider for employment qualified applicants with arrest and conviction records pursuant to applicable law.

Applicant Privacy Notice
AI Screening Notice
Ashby Bias Audit

You will receive a confirmation email once your application has successfully been accepted. If there is an error with your submission and you did not receive a confirmation email, please email careers@fluidstack.io with your resume/CV, the role you've applied for, and the date you submitted your application-- someone from our recruiting team will be in touch.
Solicitar en el sitio web original

Ashby

Solicita con una cuenta gratuita

Una cuenta gratuita muestra el enlace de solicitud original a los miembros aptos, evalúa tu compatibilidad con el puesto, lo guarda en tu seguimiento y permite que Autopilot encuentre ofertas similares.

Crear cuenta Iniciar sesión

Las cookies esenciales respaldan su sesión y seguridad. Google Analytics y la medición publicitaria de Meta solo se cargan con sus opciones individuales. El texto del CV y los datos de contacto no se envían.

Cookies esenciales · siempre activas

Sesión, protección CSRF y su preferencia de cookies. Estos permiten el acceso a la cuenta y la elección que realiza aquí.

Google Analytics mide páginas públicas y acciones predefinidas tras otorgar su consentimiento. Se excluyen el texto de búsqueda, el contenido del CV, los ID de cuenta y los tokens de pago. El almacenamiento de publicidad y la personalización permanecen desactivados.

Con el consentimiento de marketing, Meta recibe eventos PageView en páginas de presentación públicas seleccionadas, la URL de la página y la información de red/navegador para medir la publicidad. PageView excluye las páginas de CV, búsqueda de empleo, cuenta y pagos. La coincidencia automática y la recopilación automática de eventos están deshabilitadas. Meta puede procesar esta información fuera de su país. Rechazar no restringe las herramientas.

Con consentimiento de marketing, Google Ads mide cuentas verificadas y compras confirmadas con un ID anónimo e importe/divisa. Sin CV ni datos de contacto.

Con consentimiento de marketing, Meta puede guardar identificadores de clic publicitario en la página de registro para atribuir una cuenta verificada posterior. Abrir el formulario no cuenta como registro.

Con consentimiento de marketing, Meta mide también las cuentas verificadas en la página inicial del espacio de trabajo mediante un ID anónimo. Sin CV ni datos de contacto.

Su elección se almacena durante 180 días. Puede cambiarla o retirarla en cualquier momento mediante la Configuración de cookies. Rechazar la analítica no restringe las herramientas de empleo.

Política de cookies