roTEAMnet

Lead Operations Engineer, Data Center Facilities (SpaceXSI)

SpaceX · Memphis, TN

Source wording only; this is separate from professional fit. Remote does not automatically mean worldwide eligibility or flexible hours.

Original source: Greenhouse · Published 2026-11-19 · Last checked 2026-11-22 00:52 UTC

Work arrangement not specifiedLead / staff1+ yrsEngineering & technical R&DSpaceX United States

Check the requirements against your experience, prepare your document and keep the opportunity in your applications. You submit the application yourself.

SpaceX was founded under the belief that a future where humanity is out exploring the stars is fundamentally more exciting than one where we are not. Today SpaceX is actively developing the technologies to make this possible, with the ultimate goal of enabling human life on Mars.

LEAD OPERATIONS ENGINEER, DATA CENTER FACILITIES (SPACEXSI)

RESPONSIBILITIES:

Lead a team of operations and controls engineers responsible for facility automation, commissioning, and live-plant support across chillers, pumps, cooling towers, coolant distribution units, air handlers, heat rejection, and related plant equipment

Prioritize the team's design, construction, commissioning, failover, and live-event work, and define individual responsibilities

Architect, write, and debug PLC and controller code that is organized, structured, documented, maintainable, and reusable across chillers, pumps, cooling towers, coolant distribution units, air handlers, heat rejection, and related plant equipment

Implement lead/lag, staging, rotation, free-cooling, and liquid-cooling control strategies that hold capacity, efficiency, and redundancy (N+1 / 2N) as the cluster load changes

Keep the plant safe and reliable with fail-safe interlocks, emergency power off and transfer logic, and alarm philosophy that meets NEC, NFPA 70E, NFPA 75, and applicable life-safety requirements

Build clear HMI and control-room graphics so operators can see plant state, acknowledge alarms, trend equipment health, and troubleshoot without calling an engineer first

Integrate equipment controllers into the site BMS, EPMS, and historian so power, cooling, and environmental data are one operational picture

Design control panels and electrical interfaces compliant with NEC, NFPA, and UL 508A, including motor and VFD interfaces, safety circuits, and network architecture

Own the systems after go-live: alarm rationalization, loop tuning, sequence changes, outage support, and continuous improvement of uptime and energy performance

Build schedules and punch lists for controls scope and drive vendors, contractors, and internal teams to hit them during construction and live expansions

BASIC QUALIFICATIONS:

Bachelor’s degree in electrical engineering, mechanical engineering, controls, mechatronics, or engineering discipline

2+ years of experience in industrial controls, building or plant automation, data center facilities, or related programming

1+ years of experience leading a team or technical project

PREFERRED SKILLS AND EXPERIENCE:

Experience managing and developing engineers or a small technical team

Energized by fast, iterative design, construction, and commissioning on a live critical facility

Proven ability to turn a messy plant problem into a simple, reliable control solution

Clear written and verbal communication, including control narratives, sequences of operations, and recommendations across mechanical, electrical, and operations teams

Judgment to move quickly while protecting people and equipment around high voltage, stored energy, refrigerants, fuel systems, and high-pressure hydronics

Experience in data centers, power generation, district energy, industrial utilities, or other 24/7 process plants

Experience in at least one of the disciplines below, with a real interest in learning the others

Sizing and application of motors, VFDs, starters, valves, actuators, instrumentation, and circuit protection for pumps, fans, towers, and plant equipment

Design of fail-safe circuits using safety relays and safety controllers, including interlocks that must hold during a loss of power or a controls failure

Hands-on troubleshooting of industrial electrical systems with multimeters, oscilloscopes, and network diagnostics

Reading and producing schematics, panel layouts, riser diagrams, and one-line diagrams (EPLAN preferred)

Fieldbus and Ethernet plant networks: BACnet/IP, Modbus TCP, EtherNet/IP, Profinet, and OPC UA

Designing, building, and commissioning control panels and electromechanical systems with arc-flash, lockout/tagout, and construction-power constraints in mind

Working knowledge of NEC, NFPA 70E, UL 508A, and data center facility standards, with the ability to apply them to control design

PLC programming in structured text and ladder, preferably Rockwell (Studio 5000), Siemens TIA Portal, or Beckhoff TwinCAT

HMI, BMS, and SCADA development — Ignition, Niagara, or an equivalent platform — focused on fast navigation, meaningful alarms, trends, and equipment health

Industrial protocols used in critical facilities: BACnet/IP, Modbus TCP, OPC UA, MQTT, SNMP, EtherNet/IP, and Profinet

Applying control software to mechanical and electrical assemblies: sensors, VFDs, valves, and pump or fan systems, including a disciplined checkout before a system is allowed to carry load

Experience with EPMS, power metering, generator or ATS status, and historian or alarming tools used to operate a data center

ADDITIONAL REQUIREMENTS:

Ability to work long hours, nights, and weekends when commissioning, failover testing, or a live plant event requires it

Willingness to work on site in the data center, including mechanical plants, electrical rooms, and the data halls, for checkout and troubleshooting

ITAR REQUIREMENTS:

To conform to U.S. Government export regulations, applicant must be a (i) U.S. citizen or national, (ii) U.S. lawful, permanent resident (aka green card holder), (iii) Refugee under 8 U.S.C. § 1157, or (iv) Asylee under 8 U.S.C. § 1158, or be eligible to obtain the required authorizations from the U.S. Department of State. Learn more about the ITAR here.

SpaceX is an Equal Opportunity Employer; employment with SpaceX is governed on the basis of merit, competence and qualifications and will not be influenced in any manner by race, color, religion, gender, national origin/ethnicity, veteran status, disability status, age, sexual orientation, gender identity, marital status, mental or physical disability or any other legally protected status.

Applicants wishing to view a copy of SpaceX’s Affirmative Action Plan for veterans and individuals with disabilities, or applicants requiring reasonable accommodation to the application/interview process should reach out to EEOCompliance@spacex.com.
Apply on the original website

Greenhouse

Apply with a free account

A free account shows the original application link to eligible members, checks your fit with this job, saves it to your tracker and lets Autopilot find more jobs like it.

Create account Log in

Essential cookies support your session and security. Google Analytics and Meta advertising measurement load only with your separate choices. CV text and contact details are not sent.

Essential cookies · always active

Session, CSRF protection and your cookie preference. These support account access and the choice you make here.

Google Analytics measures public pages and predefined actions after consent. Search text, CV content, account IDs and payment tokens are excluded. Advertising storage and personalization remain disabled.

With marketing consent, Meta receives PageView events on selected public presentation pages, the page URL and network/browser information, to measure advertising. PageView collection excludes CV, job search, account and payment pages. Automatic matching and automatic event collection are disabled. Meta may process this information outside your country. Declining does not restrict tools.

With marketing consent, Google Ads measures verified account creation and confirmed purchases using an anonymous event ID and purchase amount/currency. No CV or contact details are sent.

With marketing consent, Meta may store advertising click identifiers on the registration page to attribute a later verified signup. Opening the form is not counted as a registration.

With marketing consent, Meta also records verified account creation on the workspace home page using an anonymous event ID. It receives no CV or contact details.

Your choice is stored for 180 days. Change or withdraw it at any time using Cookie settings. Declining analytics does not restrict career tools.

Cookie Policy