roTEAMnet

Operations Engineer, Supercompute - Memphis

SpaceXSI · Southaven, MS; Memphis, TN

Nur Quellenangaben; getrennt von fachlicher Passung. Remote bedeutet nicht automatisch weltweite Zulassung oder flexible Stunden.

Originalquelle: Greenhouse · Veröffentlicht 2026-10-23 · Zuletzt geprüft 2026-11-24 13:33 UTC

Arbeitsmodell nicht angegebenNiveau nicht angegeben2+ J.Ingenieurwesen & EntwicklungSpaceXSI Tunesien

Prüfe die Anforderungen anhand deiner Erfahrung, erstelle dein Dokument und speichere die Stelle. Du sendest die Bewerbung selbst.

SpaceX was founded under the belief that a future where humanity is out exploring the stars is fundamentally more exciting than one where we are not. Today, SpaceX is actively developing the technologies to make this possible, with the ultimate goal of making life multiplanetary and expanding consciousness to the stars.

SpaceXSI is building Super Intelligence to help humanity understand the universe. Our teams are building the full Super Intelligence stack: from our Colossus supercomputers, to Grok models, to our suite of applications, including Grok Bot, Grok Build, Grok Imagine, Grok Voice, and X. We're creating a powerful flywheel where more compute trains better models, better models power more useful products, and what we learn from people using those products shapes what we build next.

OPERATIONS ENGINEER, SUPERCOMPUTE

This team owns 100% GPU uptime, end to end, 24/7, across both compute and facility. It owns incident response and the engineering behind it, holds central control authority from the customer back to the facility, runs day-to-day sustainment of live data halls, and leads deployment engineering for new data hall bring-up. The team will also build the automation for continuous response improvement. The team is expected to have system level knowledge about the whole datacenter site, end to end. The team engineers solutions to enable GPU uptime, working directly with technicians in the datahalls and field to execute the team’s engineering planning.

RESPONSIBILITIES:

Own monitoring architecture, alerting, signal quality, and automation of monitoring across GPU and host telemetry (DCGM, Prometheus/Grafana) and facility telemetry (BMS, EPMS, DCIM, SCADA, CDU / direct liquid cooling)

Own compute hardware change incorporation - physical, firmware, software

Be part of 24/7 incident response, mitigation, and control authority - end to end - from customer impact back to the facility

Own day-to-day site sustainment operations, including resolving issues impacting rack-level compute and facility infrastructure

Disposition daily issues across both site operations (rack compute) and facility operations (power and cooling)

Lead acceptance and deployment testing campaigns to bring new data halls fully online

Develop production automation for new data hall bring-up, automation behind alerting and automated incident response

Develop and maintain standard operating procedures and planning for facility and site technicians, including change / upgrade incorporation planning on both rack level and facility

Own and document the live, changing state of data hall operation as new halls come online

Enable Site Operations and Facility Operations technicians to do their day to day jobs more efficiently and safely to increase GPU uptime

Create predictive and responsive automation to alerts and incidents to enable your response to be faster and more impactful

Lead cross-functional reliability projects spanning compute, network (InfiniBand/RoCE), storage, and facility signal boundaries, including grey failures that cross those boundaries (e.g., NVLink flapping, thermal throttling, power sequencing)

Truly root cause systemic and design failure classes across hardware and integrated facility and operations systems: turn fleet data (MTBF/AFR, repeat-RMA trends) into proactive alerting, standard responses, vendor RCA inputs, and supplier corrective actions

BASIC QUALIFICATIONS:

Bachelor's degree in mechanical, electrical, or computer engineering, or a scientific discipline and 2+ years of experience in data center, critical facilities, power plant, or large-scale compute operations; OR 6+ years of professional experience in those environments in lieu of a degree

PREFERRED SKILLS AND EXPERIENCE:

Hands-on experience with at least one of: Prometheus/Grafana, NVIDIA DCGM, or industrial telemetry and controls (SCADA, BMS/BAS, EPMS, DCIM, PLCs, Modbus/BACnet).

Experience in datacenter site reliability, systems engineering, plant operations, or large-scale production operations.

Experience running acceptance test campaigns for integrated products.

Experience in AI/ML infrastructure or supercomputing environments: GB200/NVL72 or H100/H200-class GPU fleets, NCCL, InfiniBand/RoCE, Slurm or Kubernetes.

Fleet firmware and BMC management (Redfish, IPMI), including firmware release validation and staged rollouts.

Familiarity with data center hardware and plant signals (servers, GPUs, networking, power, cooling) in addition to software telemetry.

Proven large-scale incident command experience and calm technical leadership on a bridge, whether from an SRE/NOC bridge or a plant control room.

Experience writing and operating playbooks, runbooks, or standard operating procedures, methods of procedure, emergency operations procedures.

Proficiency in scripting (Python, Bash) for automation and analysis, plus general experience in at least one systems language (C, C++, Java, Go, Rust, or similar).

Ability to work collaboratively with cross-functional, cross-country, multi-disciplinary teams.

SpaceXSI is an equal opportunity employer. For details on data processing, view our Recruitment Privacy Notice.
Auf der Originalseite bewerben

Greenhouse

Mit einem kostenlosen Konto bewerben

Ein kostenloses Konto prüft deine Passung, speichert die Stelle in deiner Übersicht und lässt Autopilot ähnliche Stellen finden. Berechtigte Mitglieder sehen den Original-Bewerbungslink.

Konto erstellen Anmelden

Notwendige Cookies sichern Sitzung und Schutz. Google Analytics und Meta-Werbemessung laden nur nach Ihrer jeweiligen Auswahl. Keine Lebenslauftexte oder Kontaktdaten.

Notwendige Cookies · immer aktiv

Sitzung, CSRF-Schutz und Cookie-Auswahl ermöglichen Kontozugriff und speichern Ihre Entscheidung.

Google Analytics misst nach Zustimmung öffentliche Seiten und festgelegte Aktionen. Suchtexte, Lebensläufe, Konto-IDs und Zahlungstoken sind ausgeschlossen. Werbespeicherung und Personalisierung bleiben deaktiviert.

Nach Marketing-Zustimmung erhält Meta PageView-Ereignisse auf ausgewählten öffentlichen Informationsseiten, Seiten-URL und Netzwerk-/Browserdaten zur Werbemessung. PageView erfasst keine Lebenslauf-, Jobsuche-, Konto- oder Zahlungsseiten. Automatischer Abgleich und automatische Ereignisse sind deaktiviert. Verarbeitung außerhalb Ihres Landes ist möglich. Ablehnen beschränkt keine Tools.

Mit Marketing-Einwilligung misst Google Ads bestätigte Konten und Käufe mit anonymer Ereignis-ID sowie Betrag/Währung. Keine Lebenslauf- oder Kontaktdaten.

Mit Marketing-Einwilligung kann Meta auf der Registrierungsseite Anzeigen-Klickkennungen speichern, um eine spätere bestätigte Anmeldung zuzuordnen. Das Öffnen des Formulars zählt nicht als Registrierung.

Mit Marketing-Einwilligung erfasst Meta auf der Workspace-Startseite auch die Konto-Bestätigung mit anonymer Ereignis-ID. Keine Lebenslauf- oder Kontaktdaten.

Ihre Auswahl wird 180 Tage gespeichert. In den Cookie-Einstellungen jederzeit ändern oder widerrufen. Ohne Analyse bleiben die Karrieretools verfügbar.

Cookie-Richtlinie