roTEAMnet

Electrical Engineer - AGL/Underground Utilities

Egis Group · Toronto, Canada

VollzeitBefristet / saisonal

Nur Quellenangaben; getrennt von fachlicher Passung. Remote bedeutet nicht automatisch weltweite Zulassung oder flexible Stunden.

Originalquelle: SmartRecruiters · Veröffentlicht 2026-11-23 · Zuletzt geprüft 2026-11-24 16:11 UTC

Arbeitsmodell nicht angegebenNiveau nicht angegeben8+ J.Elektro- & Energietechnik-IngenieurVollzeitEgis Group Kanada

Prüfe die Anforderungen anhand deiner Erfahrung, erstelle dein Dokument und speichere die Stelle. Du sendest die Bewerbung selbst.

Company Description

Ready to take the next step in your career? Join Egis and be part of our exciting growth across Canada. As a member of our global team of 23,500+ engineers, architects, scientists and consultants, you'll help deliver some of the country's most impactful infrastructure, transportation, buildings and energy projects while building a career with global opportunities and local impact.

Job Description

Electrical Engineer - AGL is a senior level engineering role based in Toronto, Ontario, Canada, supporting the planning, design, and delivery of electrical systems for Aviation projects.

The role is responsible for preparing engineering drawings, technical specifications, design documentation, and project reports while ensuring compliance with applicable electrical codes, Transport Canada, Ontario electrical codes, and airport authority standards. Responsibilities include technical coordination, design reviews, field inspections, and stakeholder collaboration throughout project delivery.

The successful candidate will have a minimum of 8+ years of electrical design experience, with direct, hands-on experience in airfield ground lighting (AGL) design on airport or aviation projects.

Key Responsibilities

Design AGL systems for airside projects, including runway, taxiway, and apron lighting, signage, guidance systems, constant current regulators (CCRs), series circuits, and electrical vault/substation integration.

Design underground duct bank and dry utility systems serving airfield lighting and power, including concrete-encased and direct-buried conduit, handholes, manholes, and directional drilling (HDD) crossings.

Perform duct bank routing, conduit sizing, cable fill calculations, bend radius assessments, cable pulling and tension checks, and spare conduit planning.

Prepare ampacity and thermal analyses for cables in duct banks, plus voltage drop, load, and CCR sizing calculations, in accordance with applicable standards.

Develop construction packages including plans, profiles, cross-sections, details, and installation specifications, with attention to airfield constraints such as phasing, outages, and NOTAMs.

Prepare and maintain engineering drawings, specifications, calculations, and technical reports to support design development, quality assurance, and project approvals.

Review designs for technical accuracy, code compliance, constructability, and conformance with project requirements.

Coordinate with civil, geotechnical, airfield pavement, structural, and other disciplines to integrate electrical infrastructure within the broader project design and resolve utility conflicts.

Liaise with airport authorities, utility owners, and regulators on approvals, airside access requirements, and design submissions.

Conduct field inspections and site reviews to verify installation quality, testing (e.g., insulation resistance, continuity), and conformance with approved designs.

Provide technical guidance and mentorship to junior engineers and designers.

Participate in client meetings and technical discussions, and support project coordination, schedule, and scope management.

Contribute to the continuous improvement of departmental standards, templates, and engineering procedures.

Qualifications

Required

Bachelor’s degree in Electrical Engineering; P.Eng. licensed in Ontario (or eligible for licensure with PEO).

8+ years of electrical design experience, with direct, hands-on experience in airfield ground lighting (AGL) design on airport or aerodrome projects.

Demonstrated experience designing underground duct banks and dry utility systems, including conduit sizing, cable fill, bend radius, and ampacity considerations.

Working knowledge of aviation and electrical standards, such as:

Transport Canada TP 312 and the Canadian Aviation Regulations (CARs)

FAA Advisory Circulars (e.g., AC 150/5340-30, AC 150/5345 series), ICAO Annex 14

Canadian Electrical Code (CSA C22.1) and the Ontario Electrical Safety Code

Strong technical writing skills, including specifications and design reports.

Ability to work within live airport environments and airside safety requirements.

Assets

Experience using AutoCAD and other electrical design software.

Experience with Toronto-area or Canadian airport authorities, or with other major North American airports.

Experience with ALCMS, CCR/regulator systems, and electrical vault design.

Experience with ampacity software or IEEE 835/Neher-McGrath calculations.

Experience with construction phasing and temporary airfield lighting during live operations.

Prior experience mentoring junior staff and leading design reviews.

Mandatory Requirement

Applicants must have proven hands-on experience designing underground duct banks. Candidates without direct duct bank design experience will not be considered.

Additional Information

Egis Canada is an equal opportunities employer offering a competitive salary and benefits to those with the skills suited to the needs of our clients. The salary range advertised may exceed the range based on several factors, including relevant education, qualifications, certifications, experience, skills, geographic location, performance, and business or organizational needs.

We welcome and encourage applications from people with disabilities. Accommodations are available upon request for candidates taking part in all aspects of the selection process.

This role is eligible for a referral bonus in line with the Referral Program. If you have been referred, please provide the name of the employee who has referred you at the time of your application.

At Egis, we embrace innovation to tackle challenges and utilize AI in our recruitment process under stringent ethics and compliance policies and in alignment with our values of being a Responsible Company, a People First Company and a Creative Company. Committed to diversity, growth and collaboration, we may leverage AI to support the recruitment process.
Auf der Originalseite bewerben

SmartRecruiters

Mit einem kostenlosen Konto bewerben

Ein kostenloses Konto prüft deine Passung, speichert die Stelle in deiner Übersicht und lässt Autopilot ähnliche Stellen finden. Berechtigte Mitglieder sehen den Original-Bewerbungslink.

Konto erstellen Anmelden

Notwendige Cookies sichern Sitzung und Schutz. Google Analytics und Meta-Werbemessung laden nur nach Ihrer jeweiligen Auswahl. Keine Lebenslauftexte oder Kontaktdaten.

Notwendige Cookies · immer aktiv

Sitzung, CSRF-Schutz und Cookie-Auswahl ermöglichen Kontozugriff und speichern Ihre Entscheidung.

Google Analytics misst nach Zustimmung öffentliche Seiten und festgelegte Aktionen. Suchtexte, Lebensläufe, Konto-IDs und Zahlungstoken sind ausgeschlossen. Werbespeicherung und Personalisierung bleiben deaktiviert.

Nach Marketing-Zustimmung erhält Meta PageView-Ereignisse auf ausgewählten öffentlichen Informationsseiten, Seiten-URL und Netzwerk-/Browserdaten zur Werbemessung. PageView erfasst keine Lebenslauf-, Jobsuche-, Konto- oder Zahlungsseiten. Automatischer Abgleich und automatische Ereignisse sind deaktiviert. Verarbeitung außerhalb Ihres Landes ist möglich. Ablehnen beschränkt keine Tools.

Mit Marketing-Einwilligung misst Google Ads bestätigte Konten und Käufe mit anonymer Ereignis-ID sowie Betrag/Währung. Keine Lebenslauf- oder Kontaktdaten.

Mit Marketing-Einwilligung kann Meta auf der Registrierungsseite Anzeigen-Klickkennungen speichern, um eine spätere bestätigte Anmeldung zuzuordnen. Das Öffnen des Formulars zählt nicht als Registrierung.

Mit Marketing-Einwilligung erfasst Meta auf der Workspace-Startseite auch die Konto-Bestätigung mit anonymer Ereignis-ID. Keine Lebenslauf- oder Kontaktdaten.

Ihre Auswahl wird 180 Tage gespeichert. In den Cookie-Einstellungen jederzeit ändern oder widerrufen. Ohne Analyse bleiben die Karrieretools verfügbar.

Cookie-Richtlinie